Instructions / Assembly
LIGHTING AND OPERATING INSTRUCTIONS
WARNING: NEVER PUT HANDS OR FACE DIRECTLY OVER BURNER WHILE LIGHTING OR WHILE
THE APPLIANCE IS LIT.
FOR MODELS WITH ADJUSTABLE REGULATOR
1. Check the casting to make sure it is set up as per the illustration (Figure 1).
2. Make certain that the regulator control is turned OFF by turning it counterclockwise until it reaches
the stop.
3. Open cylinder control valve by turning it counterclockwise as per the diagram (Figure 2).
4. Insert a multipurpose lighter through the hole in the shroud as per Figure 4, or use a paper book
match placed above the casting as per Figure 5. Turn the regulator control toward the ON position
until ignition occurs. Turning the regulator control clockwise increases the gas pressure to the
burner and hence the ame size (Figure 2). When lighting the stove, if ignition does not occur in 3 to
5 seconds, turn the regulator and cylinder valve o. Wait 5 minutes for gas to disperse. Repeat
procedure.
5. Check that the ame is blue and that the ames are emitted from every port in the casting. If not,
rotate the air shutter position until there is a blue ame. Opening the shutter too much will cause
the ame to “Li” o the burner (Figure 6). If there is a yellow ame, or if some ports have no
ame, this indicates there may be an obstruction in the venturi tube or ports. Check the
maintenance instructions on page 7 for more information regarding a yellow ame.
6. Always monitor the ame throughout the cooking process. If at any point in the cooking process the
ame is accidentally extinguished, immediately turn the regulator and cylinder valve OFF.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN FIRE, EXPLOSION, BURN HAZARD
OR CARBON MONOXIDE POISONING WHICH COULD CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.