66
White smoke may appear around the emitter grid during the first minute of initial firing.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Any modifications or adjustments made to product without prior authority from the
manufacturer will void any warranty claims. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
WARNING
TEST FIRING HEATER
Test fire heater, following the lighting instructions. Leak test all gas connections with soapy water. Soap
bubbles indicate gas leakage. DO NOT use a match to test for gas leaks.
TROUBLE SHOOTING
Problem Possible Causes
Pilot won’t light
Air in gas line
Low gas pressure
Gas line turned ‘OFF’
Blockage in gas line
Ignitor did not spark
Pilot won’t stay lit
Suspect thermocouple
Corrosion of thermocouple contact
Suspect valve
Wind exceeding 16 kph
Main burner will not light
No gas
Low gas pressure
Blockage in orifice
Manual valve not in ‘LIGHT’ position
Note: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
LIGHTING INSTRUCTIONS
1. Ensure that the control knob is off. Slowly open the
gas cylinder valve.
2. Press and turn the control knob to ‘LIGHT’ position,
the rotary piezo will make a clicking sound.
3. Check for pilot flame through pilot lighting hole. If pilot
does not light turn control knob to ‘OFF’ position and try
again from the start. Several attempts may be necessary.
4. With the pilot alight keep control knob depressed for
15 seconds then turn the control knob to ‘LOW’.
5. For maximum heat turn control knob to ‘HIGH’.
6. To turn heater off, turn control knob to ‘OFF’.
Note: Allow one minute to purge air through to pilot
after connection to a new cylinder.