Installation Guide
Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.
Power supply cord
with 3-prong grounding plug
and current detection device
Grounding-type wall
receptacle
WARNING
NOTE:
The power supply cord for this air 
conditioner contains a current detection 
device designed to reduce the risk of fire.
Please refer to the section Operation
of Current Device for details. In the event 
that the power supply cord is damaged, 
it cannot be repaired. It must be replaced 
with a cord from the manufacturer.     
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. 
Do not remove any prong from the power 
cord. 
WARNING
For Your Safety
WARNING
Prevent Accidents
WARNING
Electrical Information
Do not store or use gasoline or other flammable vapors and liquids in the vicinity 
of this or any other appliance.
Operation of Curr ent Device
(Applicable to the unit adopts current detection 
device only )
The power supply cord contains a current device that senses 
damage to the power cord. To test your power supply cord do 
the following:
1. Plug in the air conditioner.
2. The power supply cord will have TWO buttons on the plug 
 head. Press the TEST button, and you will notice a click   
 as theRESET button pops out.
3. Press the RESET button, and again you will notice a click 
 as the button engages.
4. The power supply cord is now supplying electricity to the 
 unit. (On some products, this it also indicated by a light on
 the plug head.)
3
To reduce the risk of fire, electric shock, or injury to persons when using your
air conditioner, follow basic precautions, including:
 Be sure the electrical service is adequate for the model you have chosen. This
 information can be found on the serial plate, which is located on the side of the
 the cabinet and behind the grille.
 If the air conditioneri s t o b e in  stalled in  a w indow,  cl ean both sides of the g lass   
 first. If the window is a tri ple-track type with a screen panel included, remove 
 the screen completely before installation.
 Be sure the  air c  onditionerh as b een s ecurely a nd c orrectly in stalled a ccording to 
 the installation instructions in this manual. Save this manual for possible future
 use in removing or installing this unit.
 When handling the air  conditioner,  be  careful  to  avoid  cuts f rom s  harp m  etal f ins
 on front and rear coils. 
The complete electical rating of your new room air conditioner is stated on the 
serial plate. Refer to the rating when checking the electrical requirements.
 Be sure the air conditioner is properly grounded. To minimize shock and fire 
 hazards, proper grounding is important. The power cord is equipped with a 
 three-prong grounding plug for protection against shock hazards.
 Your air conditioner must be used in a properly grounded wall receptacle. If the 
 wall receptacle you intend to use is not adequately grounded or protected by a 
 time delay fuse or circuit breaker, have a qualified electrician install the proper 
 receptacle. Ensure the receptacle is accessible after the unit installation.
 Do not run air conditioner without side protective cover in place.This could 
 result in mechanical damage within the air conditioner.
 Do not use an extension cord or an adapter plug.
IMPORTANT SAFETY INSTRUCTIONS
 Do not use this device to turn the unit on or off.
 Always make sure the RESET button is pushed in for 
 correct operation.
 The power supply must be replaced if it fails to reset when
 either the TEST button is pushed or it cannot be reset. A 
 new one can be obtained from the manufacturer.
 If power supply cord is damaged, it cannot be repaired. It 
 MUST be replaced by the manufacturer.
NOTE:
NOTE:This air conditioner is designed to be operated 
 under the following conditions:
Cooling 
operation
Outdoor temp: 
Indoor temp: 
Heating 
operation
Outdoor temp: 
O
O
23-76 F/-5-24 C
Indoor temp: 
O
O
32-80 F/0-27 C
O O O O
64-109 F/18-43 C (64-125 F/18-52 C 
for special tropical models)
O
O
62-90 F/17-32 C
Note: Performance may be reduced outside of these 
operating temperatures.