Corporate Headquarters GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Magnum S14 Convenient Switch (A member of Converter Switch family) email support@garrettcom.com Installation and User Guide www . GarrettCom . com www . GarrettCom .
S14 Convenient Switch Installation and User Guide (09/04) Magnum™ S14 Convenient Switch™ Installation and User Guide Part #: 84-00100 Rev. A (06/04) Trademarks GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
S14 Convenient Switch Installation and User Guide (09/04) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication.
S14 Convenient Switch Installation and User Guide (09/04) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www . GarrettCom .
S14 Convenient Switch Installation and User Guide (09/04) TABLE OF CONTENTS 1.0 1.1 2.0 2.1 2.2 2.3 2.4 2.5 2.6 3.0 3.1 3.2 3.3 3.4 3.5 3.6 Page SPECIFICATIONS ............................................................................... 1 Technical Specifications ..................................................................... 1 INTRODUCTION ............................................................................... 10 Inspecting the Package and the Product..................................
S14 Convenient Switch Installation and User Guide (09/04) 3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation ....... 38 3.8 Connecting Twisted Pair (RJ-45 ports).............................................. 40 3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5) ................ 41 3.8.2 Connections to NICs which support Auto-Negotiation ............. 42 4.0 OPERATION ....................................................................................... 42 4.
S14 Convenient Switch Installation and User Guide (09/04) Revisions 10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL. 06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www . GarrettCom .
S14 Convenient Switches 1.0 SPECIFICATIONS 1.1 Technical Specifications Installation and User Guide (09/04) Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.
S14 Convenient Switches Installation and User Guide (09/04) Address buffer age-out time: 300 sec.
S14 Convenient Switches Installation and User Guide (09/04) -58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests Storage Temperature, All models: -40ºF to 160ºF (-40ºC to 85ºC) Cold Start: (S14H) model to -20ºC (S14P) model to -40ºC Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude (All models): -200 to 5000ft. (-60 – 15,000 m) Conformal Coating (optional) Humidity protection Note: H and P models are designed for NEBS compliance, including, vibration, shock and altitude.
S14 Convenient Switches Installation and User Guide (09/04) –Hd, and Hi: 5.8 oz (165g) –Pd, and =Pi: 7.9 oz (225g) Cooling Method: Convection on regular model, plus the case is used as a heat sink on “H” and “P” models. POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to 500mA).
S14 Convenient Switches Installation and User Guide (09/04) Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320 power connector built-in the PS unit. Out put- 12vdc, 1 Amps Input: 100-240V AC at 47-63Hz, for “-Hd” high temp., 100-240V AC at 47-63Hz “-for Hi” models that have IEC320 power connector built-in the PS unit. Out put- 12vdc, 1.25 Amps Input: 100-240V AC at 47-63Hz, for “-Pd” high temp.
S14 Convenient Switches Installation and User Guide (09/04) -48V DC internal (range of 36 to 60V DC) t. Power Consumption: 3 watts typical, 4 watts max. Note 1: 8-15V DC can be used for dual source DC input Note 2: Internal DC power floats, user may ground “+” or “-” if desired. Port Connectors: RJ-45 Port: Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable.
S14 Convenient Switches Installation and User Guide (09/04) Mounting option for S14 Family of Switches: Metal Mounting clips for panel mounting : included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method Agency Approvals and Standard Compliance: UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A.
S14 Convenient Switches Warranty: Installation and User Guide (09/04) Three years, return to factory Made in USA www . GarrettCom .
S14 Convenient Switches 1.2 Installation and User Guide (09/04) Summary of models and descriptions: S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC, Ext. AC Hardened power supply included . S14H-12VDC = Same as S14H model, except Ext.
S14 Convenient Switches 2.0 Installation and User Guide (09/04) INTRODUCTION This section describes S14-Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during shipment or delivery.
S14 Convenient Switches Installation and User Guide (09/04) Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures. 2.
F/H PWR 3 LA3 10/100 PORT 3 Installation and User Guide (09/04) PORT 3 PORT 2 LK/ACT 10/100 LK/ACT LK/ACT 10/100 PORT4 PORT 1 POWER S14 Convenient Switches LA1 PORT 4 GarrettCom S14 Left Side View Fig. 2.2a PORT 1 Fig2.1a. Magnum S14, Front view (three RJ-45 ports on Front 10/ 100 9VDC. 1AMP –15V DC 1 Magnum S14 Convenient Switch LA2 PORT 2 LK/ACT 10/100 2 8 GarrettCom WWW.GarrettCom.Com GarrettCom Magnum S14 Convenient Switch side of the unit, as shown in Fig Fig2.2a.
S14 Convenient Switches Installation and User Guide (09/04) The Yellow label, S14 shown above in regular-package units are for office and wiring closet environments, uses an external AC power supply. A metal case with convection cooling is featured. Operation may be in 0° to 50°C ambient temperature. The units can be mounted securely on a closet wall or metal cabinet, or by using the metal panel mounting clips included. The orange-label Magnum S14H as shown above in Fig 2.
S14 Convenient Switches Installation and User Guide (09/04) available. Ambient temperature rating is up to –25°C to +60°C for any of the power input F/H PWR 3 LA3 10/100 LA4 GarrettCom F/H + 4 - 8 – 15V DC PORT 2 LK/ACT 10/100 2 PORT 3 10/ 100 PORT 3 PORT 2 LK/ACT 10/100 LK/ACT LK/ACT 10/100 PORT4 PORT 1 POWER types, AC or DC. GarrettCom S14 Left Side View Fig 2.2d 10/ 100 9VDC. 1AMP PORT 1 1 Magnum S14H Hardened Convenient Switch LA2 LA1 PORT 4 Fig 2.
S14 Convenient Switches Installation and User Guide (09/04) F/H PWR 3 LA3 10/100 PORT 2 LA1 1 PORT 1 are available. WWW.GarrettCom.Com GarrettCom Magnum S14P Premium Rated Convenient Switch Fig. 2.2e options include panel-mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC powers 10/ 100 9VDC. 1AMP Magnum S14P Premium Rated Convenient Switch extended temperature components, the S14P uses similar thermal techniques as the S14H hardened units for cooling.
S14 Convenient Switches Installation and User Guide (09/04) 2.3 Magnum S14-Series, with four (RJ-45) Copper ports The Magnum S14-Series chassis houses one main PC board. The power supply is an external AC unit or internal DC via a screw terminal block. The front side of the chassis has three twisted-pair switched ports and one port is provided on the rear side. All the four ports of the S14-Series convenient switch support auto-cross (MDIX), and perform the auto-cross in the auto-negotiation mode only.
S14 Convenient Switches Installation and User Guide (09/04) The external DC power plug connector or “jack” is in the right rear of the chassis. The internal DC input terminal block is also provided on the rear side of the unit. Port #2 has the capability to configure that port as “FF” Full-Fixed for connecting the 100Mb Full Duplex ports, or “A” to connect with an auto-negotiating port. Port #2 is controlled by the manually-selectable slide-switch (FF-A), mounted underneath the port.
S14 Convenient Switches Installation and User Guide (09/04) While other switching technologies such as "cut-through" or "express" impose minimal frame latency, they will also permit bad frames to propagate out to the Ethernet segments connected. The "cut-through" technique permits collision fragment frames, which are a result of late collisions, to be forwarded to add to the network traffic.
S14 Convenient Switches Installation and User Guide (09/04) buffering and processing resumes. This flow-control sequence occurs in a small fraction of a second and is transparent to an observer. See Section 4.6 for additional details. Another feature implemented in Magnum S14-Series Convenient Switches is a collision-based flow-control mechanism (when operating at half-duplex only).
S14 Convenient Switches Installation and User Guide (09/04) 2.5 Features and Benefits Small 4-port 10/100 Switch unit for edge-of-network applications Where a small chunk of Ethernet connectivity is needed to connect edge devices into the LAN, the Magnum S14-Series Switches provide 10/100 switching in a convenient and compact package that fits right into the site.
S14 Convenient Switches Installation and User Guide (09/04) Rugged metal case, Industrial grade S14-Series are packaged in a rugged sheet metal enclosures to ensure durability and noise immunity, even when placed in extended temperature environments or high EMI noise sites; e.g industrial or outdoor applications. AC and DC Power Supplies with extended temperature ratings S14-Series power input may be a variety of types, external AC and internal DC at 12V, 24V, or -48VDC.
S14 Convenient Switches 2.6 Applications for office S14-Series Installation and User Guide (09/04) With the three tier “YOR” hardness ratings, Yellow for “office”, Orange for “Hardened”, Red for “Premium rated (outdoor)”, the Magnum S-14 Series Convenient Switch unit fits in any environment where users need to add a few RJ-45 ports to a LAN quickly and cost effectively. The edge-of–the-network connectivity product makes challenging industrial applications easier, more economical and more-reliable.
S14 Convenient Switches Installation and User Guide (09/04) Magnum 6K25 LA3 F/H PWR LA1 1 Magnum S14 Convenient Switch LA2 PORT 2 10/100 LK/ACT GarrettCom PORT 4 1 Magnum DS80C Dual Speed Personal Hub LA3 LA3 F/H PWR WWW.GarrettCom.Com GarrettCom Magnum S14 Convenient Switch GarrettCom Magnum S14 Convenient Switch 100 Server 12V, 1.
S14 Convenient Switches Installation and User Guide (09/04) speed requirements. The users operate at 100Mb as well as at 10 Mb, and utility devices (such as print servers) run at 10 Mbps. High performance users need a high bandwidth uplink for access to a central LAN and central file servers. Any attached node can change speed at any time without affecting network operation or impacting other users. The multifunctional S14 Convenient switches provide this solution very efficiently and economically.
S14 Convenient Switches Installation and User Guide (09/04) LA3 F/H PWR Magnum 6K25 3 10/100 LK/ACT 10/100 LK/ACT PORT 3 LA1 IBM Compatible PORT 1 WWW.GarrettCom.Com 1 10/ 100 9VDC. 1AMP IBM Compatible Magnum S14 Convenient Switch 3 6 8 7 8 PORT 2 PORT 3 2 3 6 8 7 6 8 7 8 PORT 1 PORT 2 PORT 1 LA3 2 LA2 10/ 100 9VDC. 1AMP GarrettCom Magnum S14 Convenient Switch Workstation WWW.GarrettCom.
S14 Convenient Switches Installation and User Guide (09/04) the cost-effective Magnum S14Hs Convenient Switches easily qualified to use in highly controllable industrial applications. The S14H Switches act as a network edge connectivity unit to satisfy ongoing needs very efficiently and economically. Example 3: S14Ps The Magnum S14Ps fits very well in high temperature locations (control rooms) experiencing a need to scale its LAN quickly and cost effectively.
S14 Convenient Switches Installation and User Guide (09/04) Magnum 6K25 W W W .G a rr e ttC o m .
S14 Convenient Switches Installation and User Guide (09/04) In this example, the extended temperature rated S14Ps takes care of the LAN connectivity requirement in a harsh temperature environment, mounted above the ceiling in the building. The ongoing demand of growing network can be easily met by this sleek designed convenient Switch.
S14 Convenient Switches 3.0 Installation and User Guide (09/04) INSTALLATION This section describes the installation of the Magnum S14-Series Convenient Switches, including location, mountings, power supply and media connection. 3.1 Locating the Convenient Switch Unit All the S14-series Switches operate in transparent half-and full-duplex mode.
S14 Convenient Switches Installation and User Guide (09/04) an AC power outlet or power strip, and where convection cooling is not inhibited. The green Power (PWR) Led must turn ON, when power is applied through the internal DC input 12V, 24V or –48V DC or external AC through 9V DC jack. 3.2 MC14-TRAY for Rack Mounting of S14-Series Switches For 19” rack-mounting of Magnum S14-series Convenient Switches, a rack-mount tray is available, MC14-TRAY.
S14 Convenient Switches Installation and User Guide (09/04) Converters may be placed on a tray, up to a maximum of 16 units. (The mounting spaces of the MC14-TRAY are specific to the “S14”-series, and do not permit other models). A typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a few (often three to eight) S14-series Convenient Switches, with their power supplies plugged into power strips (not included) in the rear area of the tray.
S14 Convenient Switches Installation and User Guide (09/04) supporting up to 10 Switches for MC14-TR+PS9 and 16 units S14-Series for MC14TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power supply. These models are equipped with auto-ranging AC input to the power supplies for use worldwide. (The MC mounting spaces of the MC14 -TR models are specific to the Magnum S14-Series 10Mbps (FT14 and TB14) and 100Mb (14E) series, and do not permit other models to be put in the tray).
S14 Convenient Switches Installation and User Guide (09/04) installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few S14-Series , 10Mbps FT14’s and 100Mb 14E Media Converters, each with their power input plugged into the built-in common AC power supply in the rear area of the tray. (PS units that come with the MC’s are not used). Metal mounting screws in the bottom-front hold each of the media converters secure in the tray, separately removable for service.
S14 Convenient Switches Installation and User Guide (09/04) hardware is optional and needs to be ordered as a separate item, e.g. Model # DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit. The Rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.
S14 Convenient Switches Installation and User Guide (09/04) The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC power supply designed to be used with UL listed Class II power supplies and the detail info is being provided in Technical Specifications Section 1.1. The S14-Series are designed to provide reliable operation, withstand higher temperature environments, and provide the Direct DC power choices to the user to deploy in uncontrolled temperature environments.
S14 Convenient Switches Installation and User Guide (09/04) The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC and the –48V DC is provided in the Technical Specifications Section 1.1. The various models of Direct DC power type and extended ambient temperature power supplies are numerous and your choice needs to be called out on your order.
S14 Convenient Switches Installation and User Guide (09/04) models support a range of power input types. The three model choices are for use with 12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability. The extended temperature capability of the Direct DC-powered S14P’s can go into temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is also present and optionally can be used with an external P-rated AC power supply to provide “dual source” power input.
S14 Convenient Switches Input current: Installation and User Guide (09/04) 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption: 3 watts typical, 4 watts max. 3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation This section describes the proper connection of the -48VDC leads (or 24VDC, 12VDC leads) to the Direct DC power terminal block on the Magnum S14H hardened media converter (as shown in Figure above).
S14 Convenient Switches Installation and User Guide (09/04) terminals are identified as positive (+) and negative (-), and they are floating inside the unit so that either of the terminal may be grounded by the user if desired. The chassis is “earth” or ground (GND). The connection procedure is straightforward. Simply insert the DC leads to the S14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) optional; it connects to the S14H chassis.
S14 Convenient Switches Installation and User Guide (09/04) 3.8 Connecting Twisted Pair (RJ-45 ports) The Magnum S14-Series Convenient Switches can be connected to only one media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft).
S14 Convenient Switches 3.8.1 Installation and User Guide (09/04) Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables. 1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port.
S14 Convenient Switches 3.8.2 Installation and User Guide (09/04) Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of Magnum S14-Sereis Convenient Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system.
S14 Convenient Switches Installation and User Guide (09/04) The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section 2.2). When the connected device is 10 Mbps, the S14s obeys all the rules of 10 Mbps Ethernet configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can “communicate with” 100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb domain too.
S14 Convenient Switches Installation and User Guide (09/04) of the network from processing them. A packet whose destination address is on another port segment will be forwarded to the appropriate port, and will not be sent to the other ports where it is not needed. Packets needed for maintaining the operation of the network (such as occasional multi-cast packets) are forwarded to all ports.
S14 Convenient Switches Installation and User Guide (09/04) An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up. 4.2 Auto-cross (MDIX),Auto-negotiation and Speed-sensing All the four RJ-45 ports independently support auto-cross (MDIX) in autonegotiation mode for speed in 10BASE-T and 100BASE-TX modes.
S14 Convenient Switches Installation and User Guide (09/04) 4.4 Dual LEDs, Front-panel and side-panel (Magnum S14-Series) LED Description PWR Illuminates GREEN to indicate power applied. LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device. The Link ports are also represented by LA1, LA2, LA3, & LA4.
S14 Convenient Switches 5.0 TROUBLESHOOTING Installation and User Guide (09/04) All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum S14-Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in Section 4.
S14 Convenient Switches Installation and User Guide (09/04) 5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable. 2. Check the cables and connectors to ensure that they have been properly connected and the cables/wires have not been crimped or in some way impaired during installation.
S14 Convenient Switches 5. Installation and User Guide (09/04) If the problem continues after completing Step 4 above, contact your supplier of the Magnum S14-Series 10/100 Mb/s Switch unit or if unknown, contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for assistance. 5.2 When Calling for Assistance Please be prepared to provide the following information. 1. 2. 3. A complete description of the problem, including the following points: a. The nature and duration of the problem; b.
S14 Convenient Switches 4. Installation and User Guide (09/04) A record of changes that have been made to your network configuration prior to the occurrence of the problem. Any changes to system administration procedures should all be noted in this record. 5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization (RMA) number.
S14 Convenient Switches Installation and User Guide (09/04) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found.
S14 Convenient Switches Installation and User Guide (09/04) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit. 2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container. 3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Attn.: Customer Service www . GarrettCom .
S14 Convenient Switches Installation and User Guide (09/04) APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.