Magnum P62-Series Corporate Headquarters (P62F and managed mP62 models) GarrettCom, Inc. 213 Hammond Avenue Fremont, CA 94539 Phone: 510.438.9071 Fax: 510-438-9072 Web: www.GarrettCom.com Hardened Ethernet Switches Email: support@Garrettcom.com Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Magnum P62-Series (P62F and managed mP62 models) Hardened Ethernet Switches Installation and User Guide Part #: 84-00092, (Rev F 12/02) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum, Personal Switch, and Link-Loss-Learn (patent pending) are trademarks and Personal Hub is a registered trademark of Gar
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) MAGNUM ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are heavy duty, feature fiber-built-in ports, and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications.
Magnum P62-Series Hardened Switches TABLE OF CONTENTS Installation and User Guide (12/02) PAGE 1.0 SPECIFICATIONS .............................................................................................2 Technical Specifications ...................................................................................2 Ordering Information ........................................................................................5 2.0 INTRODUCTION...............................................................
Magnum P62-Series Hardened Switches 1.0 SPECIFICATIONS 1.1 Technical Specifications Installation and User Guide (12/02) Ports Performance Fiber, and when an auto-negotiating port is operating at 100Mbps: Data Rate: 100Mbps When an RJ-45 auto-negotiating port is operating at 10 Mbps: Data Rate: 10 Mbps For mP62 models, RJ-45 ports are S/W controlled for speed and F/H duplex, crossover (MDI – MDIX) is automatically handled Network Standards 100Mb: Ethernet IEEE 802.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Power Supply (Internal) 24VDC and -48VDC Power Supply Power Input Voltage: 20 to 70 VDC (auto-ranging), “-, GND, +” Power Consumption: 10 watts typical. DC-DC Converter Rating: 5VDC, 2Amps Power Supply (Ext.) 125VDC & 250VDC, (PSX-T) for P62-Series -5V only Power Input Voltage: 100 to 275 VDC (nominal rating of 125, 250VDC) Power Consumption: 15 watts typical.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) MTBF (Bellcore method) Over 10 years MTBF. Email sales@GarrettCom.com for details Agency Approvals UL Listed (UL 60950), cUL, CB, CE Low Volt. Dir. & Electro-Magnetic Comp. IEEE P1613 (Draft) Environmental Standard for Electric Power Subs. (C37.90) Emissions: meets FCC Part 15, Class A, and ETSI UL2043 fire tests for “plenum rating”. Warranty: Three years, return to factory www . GarrettCom .
Magnum P62-Series Hardened Switches 1.2 Installation and User Guide (12/02) Ordering Information Magnum P62-Series, 10/100 Ethernet Switch Magnum P62F-AC-2MSC: P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power source Extended Temp ( a separate unit).
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Managed P62-Series (mP62) Hardened Switches Magnum mP62-AC-2MSC: mP62-AC Managed Switch with six10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Software includes menu-driven user interface for ease of use, SNMP, QoS, Telnet, Security, STP, VLAN, BootP/DHCP. Has 4Knodes address table and 256K packet buffers. AC power input, 85-260vac 47-63Hz worldwide auto-ranging, via PSX-A Power Source Extended Temp (a separate unit).
Magnum P62-Series Hardened Switches 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Installation and User Guide (12/02) Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum P62-Series Hardened Switches 2.2 Installation and User Guide (12/02) Product Description The Magnum P62-Series Ethernet “Outdoor” Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high / low temperatures. Magnum P62-Series Hardened switches provide two built-in 100Mb fullduplex switched fiber ports so that several units can be daisy-chained.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) performance plug-and-play operation in a rugged package. The high-strength steel enclosure gives extra protection. Each P62-Series Hardened Switch is non-blocking on all ports and has large packet buffers and a 4K-node address table for advanced performance. A Magnum P62-Series Switch, with store-and-forward switching ability, filters all faulty packets to minimize traffic congestion. 2.2.1 Magnum P62-Series chassis w/fiber SC (m.m.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) The Magnum P62-5V models are available with an External Power Source (Optional) for power input of universal AC power using the Magnum PSX-A unit. The 125/250 VDC model (PSX-T) input power supports a range of 100-275VDC and comes with input safety shield, fuses, and is diode-protected against accidental reverse polarity connection.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) The serial (Console) port is provided on the right front of the Managed mP62 Switch to use the Console Management Interface(CMI) to manage all functions of the switch. In addition, the Link-Loss-Learn feature (patent pending) in mP62’s allows rapid operating recovery from a link loss.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) format, a separate document normally accessed via the web-browser, ftp://ftp.garrettcom.com/ or FTP client program by ftp.GarrettCom.com using user : ftpuser password : ftpuser All the MNS-mP Software related information and NEW releases related to MNS-mP Software and Hardware for mP62’s can be accessed and download from Garrettcom’s FTP site. Or please visit www.GarrettCom.
Magnum P62-Series Hardened Switches 2.3 Installation and User Guide (12/02) Fiber port, SC Connectors The Fast Ethernet fiber switched ports on the Magnum P62-Series operate at fixed 100Mb speed and full-duplex mode for the best performance. The P62’s fiber ports are factory-built as either a multi-mode or single-mode SC connector. A yellow label on the fiber port connector will indicate if it is single-mode. Otherwise it is a multi-mode port.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) To minimize the possibility of dropping frames on congested ports, each Magnum P62Series Hardened Switch dynamically allocates buffer space from an 1MB memory pool, ensuring that heavily used ports receive very large buffer space for packet storage. (Many other switches have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed number of packets to be stored per port.
Magnum P62-Series Hardened Switches 2.5 Installation and User Guide (12/02) Features and Benefits 100Mb switching services for high performance Ethernet LANs Magnum P62-Series Switches provide Fast Ethernet switching on all ports. They perform high speed filter/forward operations on the traffic, giving each port’s segment a full 100Mb (or possibly 10 Mb for RJ-45 ports) of bandwidth.
Magnum P62-Series Hardened Switches 2.6 Installation and User Guide (12/02) Applications The P62-Series is designed specifically for harsh temperature environments and brings future-proof fiber and widely-used copper connectivity to out-of-the-way sites. Example 1. Magnum P62F In this example, a Magnum P62F Hardened Switch performs roadside real time traffic data collection and transmits it to a remote control station over fiber.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Example 2. The Magnum P62F fits very well in high temperature locations (control rooms) experiencing a need to scale its LAN quickly and cost effectively. With its half / full duplex switching capability, the P62F provides a very economical high bandwidth solution at each copper-cable user-access point. The 10/100 dual-speed functions to support a mixed environment of 10 Mbps and 100Mbps users and devices.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) Example 3. Magnum mP62 PW Magnum Managed Fiber Swit GARRE 1 3 1 5 L 10/1 F/ AC F/ 2 AC AC F/ TX L T LK R 3 5 1 L 10/1 F/ AC F/ 2 AC AC F/ TX L T LK R 3 5 L 10/1 F/ AC F/ 2 AC AC F/ TX L T LK R Magnum T Magnum T Magnum Magnum T T Magnum T Magnum T Fig .2.6.
Magnum P62-Series Hardened Switches 3.0 Installation and User Guide (12/02) INSTALLATION This chapter provides instructions for installing Magnum P62-Series units. 3.1 Locating Magnum P62F-Series 10/100Mb Ethernet Switches The location of a Magnum P62-Series Hardened Switch is dependent upon the physical layout of the network. The rugged 18-gauge sheet steel case that acts as a heat sink will normally protect the P62-Series from accidental damage in any application setting.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) 20.1cm) center-to-center. Four user-supplied screws, ¼” max diameter, attach the P62’S base plate to the vertical mounting surface. The PSX Power Source mounting is similar. The mechanical drawings in Figures 1 & 2 below provide the mounting holes measurement information for the PSX unit (mounted on top, if present) and for the Magnum P62-Series unit. 3.35” (8.5) 6.13” (15.68) Fig 1. 3.35” (8.5) 3. 35” (8.5) 7. 92” (20.1) Fig.
Magnum P62-Series Hardened Switches 3.2 Installation and User Guide (12/02) Connecting Ethernet Media, and Special Strain-relief feature Note – see also “Cable Strain Relief Feature, Section 3.4. The Magnum P62-Series Ethernet Switches (P62F model illustrated here) can be connected to the following three media types: 100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
Magnum P62-Series Hardened Switches 1. 2. 3. 4. Installation and User Guide (12/02) Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. Connect the other end of the cable to the corresponding device.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) longer distances, about 20Km with the single-mode SC. The same procedures as for multi-mode fiber apply to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above. 3.2.5 Power Budget Calculations for P62-Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
Magnum P62-Series Hardened Switches 3.2.6 Installation and User Guide (12/02) Connections to NICs which support Auto-Negotiation, RJ-45 ports The copper ports of Magnum P62-Series Hardened Switches will function properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system.
Magnum P62-Series Hardened Switches 3.3.2 Installation and User Guide (12/02) Power the P62-5V models w/Ext AC Power Supply (PSX-A) The rugged Magnum P62-5V Hardened Switch, mainly used in “outdoor” Ethernet applications at extended temperatures, also supports universal AC power input from 85-275 vac 50-60Hz through a separate Power Source unit, the PSX-A. The wide range of AC power input qualifies this product for use worldwide, in almost any temperature environment.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) this product for use worldwide, in almost any temperature environment. The 125/250 VDC power source (PSX-T) provides a rugged power supply enclosed in a metal case that also acts as a heat sink, enabling extended temperatures to be accommodated. The PSX-T also includes reversepolarity protection to prevent damage in case the unit is accidentally hooked up backwards.
Magnum P62-Series Hardened Switches 3.4 Installation and User Guide (12/02) Cable Strain Relief Feature on all P62-Series models The Magnum P62-Series Hardened Switches are designed to use in extended temperature environments, which qualifying them to be used in roadside traffic data collection and control stations, above-the-ceiling locations in commercial buildings, etc. They are usually mounted vertically so that the cables hang out the bottom.
Magnum P62-Series Hardened Switches 4.0 Installation and User Guide (12/02) OPERATION This section describes the function and operation of the Magnum P62-Series Switches. 4.1 Dual-Speed Functionality, and Switching The Magnum P62-Series Hardened Switch provide six 10/100 RJ-45 switched ports, and two 100Mb fiber ports. The architecture supports a dual speed switching environment, with two built-in full-duplex “future-proof” fiber ports.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) An address-aging algorithm causes least-used addresses to fall out in favor of new frequently-used addresses. To reset the address buffer, cycle power down-and-up. 4.2 Auto-negotiation and Speed-sensing All six RJ-45 ports independently support auto-negotiation for speed in 10BASE-T and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.
Magnum P62-Series Hardened Switches 5.0 Installation and User Guide (12/02) TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation Magnum P62-Series Hardened Switch is a straightforward procedure (see INSTALLATION, Section 3); the operation is also straightforward and is discussed in Section 4.
Magnum P62-Series Hardened Switches 5.2 Installation and User Guide (12/02) When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The components involved in the problem; d. Any particular application that, when used, appears to create the problem; 2.
Magnum P62-Series Hardened Switches Installation and User Guide (12/02) GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found.