Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Magnum 6K32F, 6K32FR, 6K32FC & 6K32FRC Industrial Managed Switch Installation and User Guide Hardware User Manual www . GarrettCom . com www . GarrettCom .
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Magnum™ 6K32F, 6K32FR, 6K32FC & 6K32FRC Managed Switch Hardware Installation and User Guide Part #: 84-00103Z (Rev.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed GarrettCom, Inc. below: 47823Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) TABLE OF CONTENTS.......................................................................... Page SPECIFICATIONS ................................................................................ 1 1.0 1.1 Technical Specifications....................................................................... 1 1.2 Ordering Information ........................................................................... 4 2.0 INTRODUCTION................
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 4.4 Flow-control, IEEE 802.3x standard.................................................. 46 5.0 6K32F SERIES MANAGED SWITCH PORT MODULES............. 47 5.1 Inspecting the Package and Product................................................... 47 5.2 6KPM Module Description ................................................................ 47 5.2.1 6KP6-RJMST multi-mode FX-ST “twist lock” Module ............ 48 5.2.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The Magnum Line INDUSTRIAL NETWORKING PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc. offers the premium-quality Magnum™ line of INDUSTRIAL connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM applications where reliability is a primary consideration.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 1.0 1.1 SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet:14,880 pps Fast Ethernet: 148,800 pps Gigabit Ethernet: 1,488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5E or higher is recommended) - 100 m 1000BASE-SX, full-duplex, multi-mode(62.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Fuse Required – 3 Amps 125VDC and 100VDC Input Voltage : 88 to 300VDC Fuse Required – 1 Amp Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above Warning- All the fuse replacement must be replaced with same value.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 1.2 Ordering Information Magnum Managed Switch MODEL DESCRIPTION Magnum 6K32F or 6K32FR (Reverse model) 32-10/100 RJ-45 ports or 8 Gigabit ports managed switch with four modular slots which may be configured with a selection of 10/100/1000Mb fiber and copper connector types, max. 32 ports 10/100 or 8 ports Gigabit max., or combination.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6KP8-MTRJ 6KP8-MLC 6KP8-SLC 6KP8-45MT 6KP8-45MLC 6KP8-45SLC 6KP6-MT10ST 6KP6-RJ10ST 6KP8-45-2MT 6KP8-45-2SLC SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors SFF Fiber module, w/eight 100Mbps mm FX LC connectors SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors “4+4” module, w/four RJ-45 ports and fo
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) GBIC-TP GBIC transceiver module for use in GBPM-xOTX. One 802.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6K32F Series PoE Modules with 48VDC Pass-Through Configuration options: All module slots of 6K32F Series switch with 48VDC power input may be configured with a PoE Module (typical configuration has slot A loaded first with PoE module) P6KP8-RJ45 8 port PoE module for 6Ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6K32F Series PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input Configuration options: only one A, B, C or D (left to right) module slot of 6K32F Series switch with 48VDC power input may be configured with a PoE Module (typical configuration has slot A loaded with PoE module) 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-width rack-mount 6K switch w
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.0 2.1 Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.2 Product Description – Magnum 6K32FC / FRC (Convection cooled - No-fans) Managed Switch All of the Magnum 6K32F Series of Ethernet Switches comply with IEC61850 and IEEE1613 Utility Automation and other industry standards.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) switching services for both “smooth” streaming and “bursty” data traffic. For redundant LANs it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP. Optional Security features include SNMPv3, SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged VLANs as well as a secure, user friendly web based option.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) AC, and –48VDC power input options are designed for Telco environments, while the 24VDC is designed for Industrial/Control Room applications. The 125 & 250VDC versions are for power sub stations applications. Designed primarily for use in harsh, un-controlled temperature industrial applications, the Magnum 6K32FC / FRC provides secure, high performance plug-andplay hardware operation, 802.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) designed to meet the future demand of Ethernet requirements with cost-effective secure solutions. The Magnum 6K32F is also available in a Reverse model option, where the LEDs are on the front and the available ports along with the power supply area found on the rear side. This configuration is mostly used for the carrier-class market.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port. 2.2.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.2.3a PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mb The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the IEEE802.3af PoE standard. Only 4 x RJ-45 (10/100) ports max. support POE(Power Inside) option in one rack mounted 6K-unit.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) modules. Please check the ordering information Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to an 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.2.5 Four-Port 10 Mb mm Fiber ST Modules The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present, ports 3, 4, 7, 8 are not present.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The 1000Mb Gigabit fiber-port modules on the Magnum 6K32F Series switches are normally set (factory default) to operate at AUTO mode for best fiber distance and performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX transceivers are compatible with the IEEE 802.3z Gigabit standards. There are two LEDs mounted on each Gigabit port module.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) When the Magnum 6K32F Series Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which allows a traffic catch-up to occur without dropping packets. Then, normal packet buffering and processing resumes.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2.3 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6K32F Series Switches provide non-blocking (all ports can run at full speed at once) performance with standard Managed Networks Software (MNS-6K) included. They are typically used in LAN traffic centers with 24 10/100Mb ports or one or two Gigabit ports for backbone connections where managed network services are desired.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) client for IP configuring, Radius X, TACACS+ etc. MDI-MDIX Auto-negotiating on RJ-45 ports for convenient cascading using straight RJ-45 cable. Supports PoE module to provide power via RJ-45 cable on the modular slots. 2.4 Applications Magnum 6K32F Series Fiber Switches offer high performance along with four modular slot options to fulfill the choice of copper/Fiber, 10,100 or 1000Mb requirements.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The modularity of the 6K32F Series Managed Switch makes it an attractive choice for use in applications with LAN connections to an organization’s multiple site offices. The different offices can be easily connected together with the Fiber ports supported by the Magnum 6K32F Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to one or two full duplex Gigabit Fiber ports.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) managed to provide easy, detectable, uninterrupted support through a viewable SNMP monitor. The Magnum 6K32F Series Managed Switch equipped with copper and optional Gigabit fiber ports on modular slots provide an economical and seamless solution to the requirements.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6K32F Series in a Redundant application Example 4: In a “ (video+data)” application where a network being designed to catered the need of multicast streaming and broadcast traffic of higher bandwidth to provide a video conferencing and video in demand channel option to the user. The Magnum 6K32F Series with two slots filled with Gigabit modules and a robust management firmware with MNS-6K qualify this requirement efficiently.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K32F Series to meet the fastest growing application of video monitoring or video surveillance demand of industry and provide an economical and effective solution to meet that expectation. Figure 4: A multicast traffic through a 6K32F Series Switches using IGMPL2 mode feature with Gigabit redundancy www . GarrettCom .
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.0 Installation Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 60C for 6K32F Series Switches. 2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and safe operation. 3.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.2 Connecting Ethernet Media The Magnum 6K32F Series Switches are specifically designed to support all standard Ethernet media types within a single Switch unit. This is accomplished by using a family of different port Modules which can be individually selected and configured per-port. See Section 2.4 for a description of the PMs. The various media types supported along with the corresponding IEEE 802.3 and 802.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this. 5. The LINK LED on the front of the PM will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after the cable is connected, the normal cause is improper cable polarity.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device 3.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both telecommunication and data communications applications. Due to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice for various applications.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The various SFPs transceivers supported by GarrettCom 6KQs D slot are- Module Model# Gigabit Gb Modules, fixed ports--SFP (Small Form Factor) 6KP2-2GSFP 2 SFP 6KP2-1GSFP1CU 1SFP 1 CU 6KP1-1SFP 1SFP 6KP1-1GCU 1 CU Gb SFP fiber optic transceivers SFP-SX Gb SX, 850nm wavelength, 500 m distance SFP-LX10 Gb LX, 1310nm wavelength, 10km dist SFP-LX25 Gb LX, 1310nm wavelength, 25km distance SFP-ZX40 Gb ZX, 1550nm wavelength,
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40) and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’) web sites and catalogs to provide guidance to network designers and installers. Fiber Port Module Speed, 6KP4F10ST 10Mb MultiMode FL Std. Mode Std.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.3 Table-Top or Shelf Mounting The Magnum 6K32F Series Managed Switches can be easily mounted on a table-top or any suitable horizontal surface. They have four rubber feet to provide stability without scratching finished surfaces. 3.3.1 Rack-mounting (for 19” RETMA racks) Magnum 6K32F & 6K32FC Installation of a Magnum 6K32F & 6K32FC Fiber Switch in a 19” rack is a simple procedure. The units are 1U (1.70”) high.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a package, along with the necessary screws for attaching the brackets to the sides of the Magnum Switch unit. They must be ordered as separate line items. 3.3.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The 32-port units will consume over 30 watts of power typically. When connecting the Ethernet cabling, there is no need to power down the unit. Individual segments can be connected or disconnected without concern for AC power-related problems or damage to the unit.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.5 6K32F Series Port Module (6KPM) Installation The Magnum 6K32F Series Switches are received from the factory with the customers required 6KPM modules installed. There may be situations where 6KPM cards need to be added or replaced. In cases where a 6KPM module needs to be added in the modular slots, the faceplate for an available front-mounted slot must be removed. The following procedure describes this operation. 3.5.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Step 2. Remove Chassis Cover The Magnum 6K32F chassis are combined with top, bottom and module panel parts and assembled together with the help of 34 Philips-head screws. First Remove the side panel (2 screws located on the right side of chassis). Second, remove the module panel screws (total 16) as shown in the fig 3.5.1a. Third, remove the top cover screws (16 screws).
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Looking down into the Magnum 6K32F Series unit, notice that there are individual PM installation spaces and female latch (white) connectors provided on the far right side of the main board along with four stand-off’s for 6KPM card position. (See Figure 3.5.1c). Figure 3.5.1c: Magnum 6K32F Series modular slot side (front-right side), without chassis cover 3.5.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Step 3. The figure here illustrates the basic layout of an individual PM card. 6KPM card fits into the space provided on the main board over the grand-daughter Bd. and the male latched cream color connectors( as shown in below fig. with arrow mark). Fig 3.5.2b: Daughter Board shown upside down with two male latch connectors Step 4.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) NOTE:. When leaving 6KPM slots empty, always use a face plate (Magnum 6KMBLNK) to cover the slot opening in the front panel. This will maintain proper cooling air flow, safety, and operation as required by FCC, CE, and other regulations. Step 6. Now screw down the daughter board with 7 #4-40 screws, except the last two at the end, so that it holds the daughter board securely.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Step 2. Remove retaining screws placed on top for the 6KPM On the top of the daughter module there are seven retaining screws for each 6KPM card. These screws are used to secure a 6KPM card in position (see Figure 3.5.3a). Remove the three standoffs holding the Granddaughter board with the chassis. Figure 3.5.3a: Top View – 7 retaining screws shown by arrows Step 3.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 3.6 Connecting the Console Terminal to Magnum 6K32F Series (Management) Use a DB-9 “null modem” cable to connect the Magnum 6K32F Series Console Port (the RS-232 port on the 6K32F Switch) to the your PC, so that your PC becomes the 6K32F’s Console Terminal. Note: The DB-9 cable does is not included with the 6K32F Series package.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) connect directly to the switch using a straight through cable. Note: For using Console port to configure the managed switch, a serial (Null-modem) female to female cable is required to communicate properly.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 4.0 OPERATION This chapter describes the functions and operation of the Magnum 6K32F Series Switch. 4.1 Switching Functionality A Magnum 6K32F Series provides switched connectivity at Ethernet wire- speed among all of its ports. The Magnum 6K32F Series support 10/100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 4.2 Status LEDs For all Magnum 6K32F Series models : PWR: LK: ACT: F/H: Power LED, ON when external power is applied to the unit. Steady ON, Link status for 10 Mbps and 100Mbps operation. ON with port activity for 10 Mbps and 100Mbps operation. Full / Half duplex LED, ON when the port is running full duplex, OFF for half duplex. 100/10: Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps 4.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) When Magnum 6K32F Series RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports. These are: (1) 100Mb fullduplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex. General information Auto-negotiation per-port for 802.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets. The transmitting device is commanded to stop transmitting into the 6K32F’s Switch port for sufficient time to let the Switch reduce the buffer space used.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) modular slot. Since the Magnum 6K32F Series Switches have dual-speed capability for copper ports, the 6 or 8-port interfaces are designed to support all standard Ethernet media types at 10 or 100Mps speed. Each 6K32F PM can provide two, four, six or eight ports for connecting Ethernet segments with its individual connector type and media. For a list of 6K32F Series Port Module types, refer to Section 1.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) connector functions as a fiber optic transceiver to support 10BASE-FX network segments. When installed in a Magnum 6K32F Series Managed Switch, the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up to the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-duplex and half-duplex.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb ST module allows it to connect the 100Mb demand of the Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a special order).
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) functions in one module of the 6K32F Series Switch supporting four Copper and two single-mode fiber network segments. The 6KP6-RJSSC, when installed in a Magnum 6K32F Series Switch operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much as 25+ Km (see Power Budget, Section 4.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) indicating proper connectivity with the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the LED is OFF. 5.2.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) the same as the ST and SC-types. It has the same LEDs per port indicating port activity (ACT), Link (LK), and FDX or HDX operation 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode 5.2.6 FX , MTRJ Small-Form-Factor The Magnum 6KP8-45MT Module is a combo module with copper and fiber (Small Form Factor) MTRJ type ports. The small size of MTRJ connectors give an advantage of placing more ports on one module.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). 5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector The Magnum 6KP8-45LC Module is a combo module with a combination of copper and Fiber (Small Form Factor) LC type ports. The small size of LC connectors allows an advantage of having more ports on one module.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, a FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a “10/100” LED indicating 100Mb when lit (or 10 Mbps when off).
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) information Sec.1.2 for all the various P6K PoE modules option. The LEDs on 6KP8-RJ45- PoE modules are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to an 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. PoE does not affect operation of Ethernet data traffic.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) traffic is not affected by PoE. LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK/ACT, as shown in the diagram. PoE LEDs Summary • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint devices. The PoE LED is ON when the attached PD is drawing power from the port. • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port and the PoE LED is OFF.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor The Magnum 6KP845SLC eight port Module is a combo module with copper and fiber (Small Form Factor) LC type fiber ports. The small size of LC connectors give an advantage of placing more ports on one module. The 6KP8-452SLC is equipped with 6 10/100 RJ-45 ports and 2 Single-mode fiber ports.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 5.2.12a GBPM-2OTX (Two Gigabit option) The Magnum 6K32-Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM-2OTX (2 x Giga module). While up to two Gigabit modules (max.) can be configured in the modular slot for GBPM-2OTX.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports) as shown below in the above figure. Each port has an Activity (ACT) LED indicating packets being received and a link (LK) LED indicating proper connectivity with the remote device when lit. 5.2.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable. 2.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 2. An accurate list of GarrettCom product model(s) involved, with serial number(s). Include the date(s) that you purchased the products from your supplier. 3. It is useful to include other network equipment models and related hardware, including personal computers, workstations, terminals and printers; plus, the various network media types being used. 4.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) 6.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) APPENDIX B : Internal DC Power Supply Options B1.0 SPECIFICATIONS FOR MAGNUM 6K32F SERIES SWITCHES, DC POWER Power Supply (Internal -48VDC Option) DC Power Connector: 3 terminals: “-“, “GND”, “+” Input Voltage: 36 - 70 VDC Power Consumption: Same as for AC models (see Section 1.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) B3.0 APPLICATIONS FOR DC POWERED SWITCHES Magnum 6K32F Series Fiber Switches are easily installed in a variety of applications where -48VDC, 24VDC and 125VDC power is used as the primary power source. The- 48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a Managed Switch.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Note: The GND should be hooked up first. The 6K32F unit has a floating ground, so the user may elect to Ground either + or - terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) APPENDIX C: Internal DC Dual-Source Power Option C1.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION The Dual-Source DC power option is designed using diodes inside of the chassis on each DC power input line. A diode is placed in each of the four input lines (behind the four external power connection terminals) so that power from an external source can only flow into the unit. This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs C4.
Magnum 6K32F/FR/FC/FRC Managed Switch Installation and User Guide (05/08) Note: The GND should be hooked up first. The 6K32F Series units have a floating ground, so the user may elect to Ground either + or - terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”.