Magnum 6K16-Series Corporate Headquarters Managed Fiber Switch GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Two 6K16s mounted side-by-side on Tray Magnum 6K16V mounted vertically Hardware Installation and User Guide www . GarrettCom . com www . GarrettCom .
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Magnum™ 6K16-Series Managed Fiber Switch Hardware Installation and User Guide Part #: 84-00136 (Rev. B) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Table of Contents.............................................................................. Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Ordering Information ........................................................................... 4 2.0 Introduction.............
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) OPERATION ....................................................................................... 42 4.0 4.1 Switching Functionality ..................................................................... 42 4.2 Status LEDs ....................................................................................... 43 4.3 Up-link Manual Switches set as (=) , for RJ-45 port only ................. 43 4.
Magnum 6K16-Series Managed Fiber Switch Installation & User Guide (04/06) Revisions 06/07: Minor updates to power supply ratings 05/07: minor update to notes for power substations 04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 02/05: minor updates and tweaks on LC port module 07/04 : 6K16 carrier class managed switch has been added with 6K16V 01/04 : Added Section 3.5 (Alarm Contacts) and 3.7.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) THE MAGNUM LINE Industrial networking products "Designed and Manufactured in the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM™ LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRYSTANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE, CARRIER CLASS, POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 1.0 1.1 SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet(1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Fiber Single-mode connector types: Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules LEDs: Per Port (one set at the port, one set on rear top) 6K16V only Per Port (one set at the port) 6K16 LK: Steady ON when media link is operational ACT: ON with receiver port activity FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode 100/10: ON =
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) For DC internal power supplies at –48VDC, 24VDC and 125VDC, including Dual Source options (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C. Per-port MDI or MDIX on RJ-45 The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 ports., and eliminate the use of cross-over cable between the devices.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 1.2 Ordering Information Magnum Managed Fiber Switch (16 ports max) MODEL DESCRIPTION Magnum 6K16V -Magnum 6K16V Managed Fiber Switch, base unit for vertical mounting. Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 16 total ports max. Two metal brackets for vertical wall or panel mounting. Wire speed filtering and forwarding across all ports, 802.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) GBPMV-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two GBIC open transceiver port for a user-selectable GBIC transceiver module GBPMV-COTX One slot Gigabit 6K module for 6K16-Series Switches, uses one 6K16Series slot and provides one GBIC open transceiver port for a user-selectable GBIC transceiver module DIN-RAIL-VRM Set of two DIN-Rail holders for a secure vertical mount of a 6K16Series unit, with screws to a
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Gigabit (1000Mb) module option for Magnum 6K16V 6KP5-G4RJ “G+2” module, w/one GBIC transceiver and four 10/100 RJ-45 connectors 6KP3-G2SC “G+2” module, w/one GBIC transceiver and two 100Mb 2km FX SC fiber ports connector GBPM-2OTX Two-port Gigabit 6K module for 6K16-Series Switches, provides two GBIC open transceiver port for a user-selectable GBIC transceiver module GBPM-COTX One slot Gigabit 6K module for 6K16-Series Switches, use
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 6K PoE Modules with 48VDC Pass-Through Configuration options: only one A, B or C module slot of 6K-Series switch with 48VDC power input may be configured with a PoE Modules New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source 10/100 auto-negotiating auto cross RJ-45 ports.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.0 2.1 Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.2 Product Description - Magnum 6K16-Series (6K16/6K16V) Magnum 6K16-Series Managed Switches, available as Magnum 6K16 and 6K16V models, and equipped with 16 modular ports, is specially designed to focus on two different aspects of Ethernet markets to meet their needs and requirements.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Security with control via Web and command line interface (CLI). For high availability LANs using ring topologies, Spanning Tree Protocol, Link-Loss-Learn and S-Ring are available. See the Managed Networks Software (MNS-6K) and S-Ring datasheets for additional details on the comprehensive set of software programs and options.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) choice of popular DC options or industry standard AC internal input. The plug-n-play Magnum 6K16V managed fiber switch, should be mounted vertically using the vertical mounting brackets which come with the unit or by using the DINRAIL-KIT (optional) for Din rail mounting. Loaded with versatile management software (MNS-6K), the 6K16V switch can be easily managed and monitored.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) requirement of this space. Magnum 6K management features not only allow the easy monitoring of the switch through SNMP, but also protect the network through its security features of port-security, SNMP3, VLAN etc.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.2.1c Magnum 6K16-Series family (6K16 and 6K16V), At a glance Comparison chart 6K16 Features 6K16V Mounting Cooling Horizontal, Rack-mount Vertical, Din-Rail Panel fan cooled, 3 fans Convection Temp. Rating Office & Factory Regular e.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) In an eight-port SFF fiber port module, all of the fiber ports are of the same speed (100Mb), mode, and connector type. Models are available with Small Form Factor (SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type connectors. The 100Mb fiber eight-port modules for the Magnum 6K16-Series’s normally are set (factory default) to operate in full-duplex mode for best fiber distance and performance.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) On the model 6K8-RJ45 module, there are four LEDs for each port, two in the connector and two separate. The LK (Link) LED indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF (when autonegotiation is not disabled).
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The LEDs on 6KP8-RJ45- PoE module are slightly different compared to regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when connected properly to a 803.af compliant PD device on that port. When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by PoE.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.2.6 Four-Port 10 Mb and 100Mb mm Fiber ST Modules ACT F/H 1 TX LK RX ACT F/H 2 TX LK RX ACT F/H TX LK RX 5 ACT F/H LK R 6 T The 4-port @10Mb ST fiber modules behave the same as the 4@100Mb ST fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are present, ports 3, 4. 7, 8 are not present. There is also a similar 100Mb fiber SC module.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The 1000Mb Gigabit fiber-port modules on the Magnum 6K16-Series are normally set (factory default) to operate at AUTO mode for best fiber distance and performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX transceivers are compatible with the IEEE 802.3z Gigabit standards. There are two LEDs mounted on each Gigabit port module.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Model # GBIC Description GBIC-SXSC One 1000BASE-SX port with multi-mode SC fiber connector GBIC-LXSC10 One 1000BASE-LX/LH port 1310nm singlemode SC 10Km GBIC-LXSC25 One 1000BASE-LX/LH port 1310nm singlemode SC 25Km GBIC-TP One IEEE 802.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.2.9 Frame Buffering and Flow Control Magnum 6K16-Series’s are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e., are good packets.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) All MNS-6K software information, including new releases and upgrades related to MNS6K software, can be accessed and download from GarrettCom’s FTP site. Alternatively, for documentation and latest information, or needed GarrettCom proprietary MIBs for SNMPwww.GarrettCom.com/techsupport/index.htm#software and look for Magnum MNS-6K info..
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.3 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6K16-Series Switches provide non-blocking (all ports can run at full speed at once) performance with standard Managed Networks Software (MNS-6K) included. They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for backbone connections, where managed network services are desired. Switching services includes 802.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 2.4 Applications Magnum 6K16-Series Fiber Switches offer high performance, modularity and availability. They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit(1000Mb) ports, with industry-standard LAN management software.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The option for setting the ports at 10 or 100Mb on copper, and supporting the 10 or 100Mb fiber media, provide a very widespread option to the users to mix match their legacy and advance network needs. The modularity of the 6K16-Series Managed Fiber Switch makes it an attractive choice for use in applications with LAN connections to an organization’s multiple site offices and factory- floors.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) running in mili-seconds . The ring topology of the network consists of high speed LAN segments supported by 100Mbps full-duplex future-proof fiber media to provide secure long distance LAN connection. The entire network is sharing a higher bandwidth Gigabit-enabled data-mining server for the vital database located in a separate secured building.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Example 3. In another application, in a Telco environment, 12 port Nebs compliant, -48VDC operated managed switch is required to meet the fiber and copper connection to store the sensitive datas. The switch must be snmp enabled and managed to easily manage the whole setup. Magnum 6K16, managed carrier class switch easily qualifies for this requirement with all the features and modularity.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.0 Installation Before installing the equipment, it is necessary to take the following precautions: 1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 500C. 2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe operation. 3.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) IEEE Standard Media Type Max. Distance Port Module Fiber: mm1 Fiber 220m ( ft) GBIC-SXSC sgl.m2 Fiber 5Km GBIC-LXSC mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST 100BASE-FX sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor mm1 Fiber small form factor sgl.m1 Fiber 15 km 6KP8V- SLC Copper: 10BASE-T and 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45 100BASE-FX 1 mm = multi-mode 3.2.1 2 sgl.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.2.3 Connecting Single-Mode Fiber Optic When using single-mode fiber cable, be sure to use single-mode fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively).
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded) The RJ-45 Gigabit ports of the Magnum 6K16-Series can be connected to the media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable is recommended to use when making 1000BASE-TX connections.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) provided on the sides of 6K16V for DIN-Rail mounting purposes. See side view at the left, with the top of the unit pointed to the right. The required two screws are included with the DIN-Rail brackets, and are no.10-32 X 3/8 PHIL. PAN w/star washer. The two heavy duty Din-Rail latches are designed as if that they can be manually accessed from the top when the 6K16V is installed on a DIN Rail.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The DIN-Rail mounting brackets and latches are optional and need to be ordered as separate items, e.g Model # DIN-RAIL-VRM 3.3.1 Mounting Dimensions for 6K16Vwith metal brackets Each Mangum 6K16V is supplied with metal mounting brackets and screws to mount the unit securely. It is recommended to mount the 6K16V vertically, as shown below, for proper cooling and long-life reliability.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.3.2 Rack-mounting options (Magnum 6K16) for Telco and ETSI Standard Magnum 6K16, a carrier class focused managed switch can be mounted as rack-mount using the following kit options offered for this product – K16-RMB Set of two rack-mount brackets for one 6K16 unit in a 19” RETMA 1U rack space, with screws to attach the metal mounting brackets to the case. Can add Model K16EXTN-KIT to extend to ETSI and 23” rack width.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.4 Powering the Magnum 6K16-Series Managed Fiber Switch The Magnum 6K16-Series Switches incorporate an internal universal power supply and have a recessed male IEC connector for the AC power cord at the left-rear. A manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped within the United States and Canada.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) power on the main board inside of the 6K16. This provides a “Hardware Alarm” because the NC contacts will open when internal power is lost, either from an external power down condition or by the failure of the power supply inside of the Magnum 6K16 Switch. Useful info. about Alarm contacts: 1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply 2. The top two pins (1,2) are software operated 3.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Step 1. Make sure the 6KPM Card package has all necessary accessories to install it properly. Each 6KPM Card package except the Gigabit, for field installation contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8 stand offs for Granddaughter board, 6 standoff for daughter Board, nine #4-40 Pan-Head screws along with Front panel face plate package.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) When the chassis top cover has been removed, the interior of the unit is exposed. Looking down into the Magnum 6K16-Series unit, notice that there are individual PM installation spaces and female latch (white) connectors provided on the main board along with four stand-off’s for each 6KPM card position. (See Figure 3.6.1b) above. Step 3.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Step 3. The figure here illustrates the basic layout of an individual PM card. Each 6KPM card fits into the space provided on the main board. Fig. 3.6.2c Daughter Board, top view of 4 copper 10/100 ports Uplink Switch Fig 3.6.2d Daughter Board shown upside down with two male latch connectors Step 4.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Step 5. Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then press slowly and firmly with two fingers (as shown below in Fig. 3.6.2f) on the top of the latching connectors until the connectors latched up securely. Figure 3.6.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Step 8. Once all 6KPM cards have been installed (including faceplates for empty slots), the chassis cover should be replaced. Make sure the chassis cover is aligned properly before securing the enclosure. 3.6.3 Removing 6KPM Cards To properly remove a 6KPM card from the 6K16-Series Managed Fiber Switch, follow the 3 steps below. Step 1. Remove chassis cover See procedures in Section 3.6.1 above.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3.7 Series Connecting a Management Console Terminal to Magnum 6K16Use a DB-9 “null modem” cable (use on any serial port)or “one DB-9 and one USB” ( USB port on the laptop) null modem cable to connect the Magnum6K16-Series Console Port (the RS-232 port on the 6K16-Series Switch) to the your PC, so that your PC becomes the 6K16-Series’s Console Terminal.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) NOTE for Power Substations: In support of the IEEE 1613 Class 2 standard, GCI advises that, for substation applications, the serial RJ-45console ports are intended for temporary connectivity to other equipment such as PCs. Since the console port connection is temporary, it is excluded from IEEE 1613 packetloss testing per the 1613 standard-defined test procedure. 4.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Address Learning All Magnum 6K16-Series units have address table capacities of 4K node addresses suitable for use in larger networks. They are self-learning, so as nodes are added, removed or moved from one segment to another, the 6K16-Series Switch automatically keeps up with node locations. An address-aging algorithm causes least-used addresses to fall out in favor of frequently-used addresses.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) One frequently-used application for the Managed Magnum 6K16-Series Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone, or to some other remote 100Mb device. In this case, it is desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode depending on the capabilities of the remote device.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) • NOTE – Some NIC cards only auto-negotiate when the computer system that they are in is powered up. These are exceptions to the “negotiate at LINK – enabled” rule above, but may be occasionally encountered. When operating in 100Mb half-duplex mode, cable distances and hop-counts may be limited within that collision domain. The Path Delay Value (PDV) bit-times must account for all devices and cable lengths within that domain.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km and the “Cable Loss” for 9/125 (Single-mode) is 0.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) * Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only if the following factors are both applied: • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Note: The 6K16V Port modules are exactly similar in the functions, size and price, compared to 6K16 but addressed as e.g 6KP8V-RJ45 . For a correct list of 6K16/6K16V Port Module types, refer to Section 1.2 Each 6K16-Series PM is individually described in the following sections. NOTE: The port #1 on the RJ-45 ports on all the modules, either all RJ-45 ports or used for COMBO module is set as (=) other user ports. 5.2.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at fullduplex and half-duplex. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps. 5.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) module with two 10Mb + two 100Mb multi-mode fiber module and in combine 4 STFiber ports. All four fiber ports are ST connectors and configured as 10Mb Half-duplex by default for 10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb STfiber ports allow the user to connect their legacy 10Mb network to the Magnum 6K16Series switch.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC6KP6-RJMSSC, type, “snap-in” connector 4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port 2 The Magnum 6KP6-RJSSC is also a Combo module 1 3 5 1 7 LK 10/100 equipped with 4 dual speed copper ports and 2 Single- 4 provides an advantage through combining copper ACT F/H F/H 2 mode SC-type connectors.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is ON and 10 Mb, when the LED is OFF. 5.2.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) (ACT), Link (LK), and FDX or HDX operation. 5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-FormFactor and 2@ 10Mb Multi-mode ST-Fiber port The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor with two different speeds. The top four ports of MTRJ Small form factor fiber support at 100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb half-duplex.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector SmallForm Factor Magnum 6KP8-MLC is a eight- 8-Port@ 100Mbps multi-mode LC fiber port port multi-mode fiber LC connector 3 “small-form-factor” used primarily in 1 3 5 ACT F/H ACT F/ ACT 2 LK F/ 2 4 LK LK 6 LK LK 6 F/H When installed in a Magnum 6K16-Series ACT ACT F/H ACT F/ ACT F/ 100Mbps fiber-to-the-desktop links.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) ports on one module. The 6KP8-45LC is equipped with 4 10/100 RJ-45 ports and 4 LC ( Small form factor) multi-mode fiber ports. When installed in a Magnum 6K16-Series Switch, it supports the standard distances as per mentioned on 5.2.8. and the LEDs also acts similarly as mentioned above. 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port The 6KP8-RJ45 module supports Ethernet twisted pair segments of any standard length.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 5.2.10 8-port New PoE(Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have capability of providing power on each port to power up the PD devices, per the IEEE802.3af PoE 6KP8-45RJ standard.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) • In the case where the 48VDC power in not internally connected and no power is coming to the PoE ports for some reason, all the PoE port LEDs are ON simultaneously to indicate a trouble condition. The ports will still operate properly for data traffic. 5.2.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The GBIC transceiver has been offered in the modular slot with multiple options as per the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ45), whereas the single Gigabit module comes in two different flavor of G+2 (100Mb fiber ports) or G+4(10/100 RJ-45 ports) as shown in the above figure. The GBIC transceiver is fastened using snap-in clips.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) when lit. 5.2.14 GBPM-2OTX (Two Gigabit option) The Magnum 6K16-Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM-2OTX (2 x Giga module). While up to two Gigabit modules (maxm.) can be configured in the modular slot for GBPM-2OTX.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support. 6.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual. Also check to make sure that the various components of the network are interoperable. 2.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 3. It is useful to include other network equipment models and related hardware, including personal computers, workstations, terminals and printers; plus, the various network media types being used. 4. A record of changes that have been made to your network configuration prior to the occurrence of the problem. Any changes to system administration procedures should all be noted in this record. 6.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) 4. Ship the package to: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Attn.: Customer Service APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) Input Voltage: 115 to 150 VDC (125VDC) Input current: 0.3Amps max.(for all RJ-45 ports) Input current: 0.35Amps max.(for all Fiber ports) Power Consumption: 50 watts max., for fully loaded (fiber ports) (24V, -48V, 125V)DC 30 watts typical for all (RJ-45 Ports) Input Voltage: 5VDC (+) or (-) 5% (5VDC) Input current: 3.5Amps max.(for all RJ-45 ports) Input current: 8.0Amps max.(for all Fiber ports) Power Consumption: 20 watts max.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) options are mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial environment, such as factory floor, HVAC equipment, military equipment, etc. The 5VDC options are mainly used for military or Industrial factory floor applications. B4.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) B5.0 OPERATION Operation of Magnum 6K16-Series Switches with the optional -48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-powered models. B6.0 ORDERING INFORMATION To order the optional -48VDC power supply factory installed, add a suffix of “- -48VDC” after the product’s standard model # Example: Magnum 6K16-SeriesR48VDC.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) C2.0 MAGNUM 6K16-SERIES, with -48VDC, 24VDC and 125VDC Dual-Source option The 6K16-Series-Switch models with the internal -48VDC, 24VDC and 125VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance.
Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06) The -48VDC terminal block on the Magnum 6K16-Series Switch, as shown in Fig C5.0 is located on the left front of the unit and is equipped with five (5) screw-down lead posts. The primary terminals are identified as positive (A+), negative (A-), and the secondary power terminals as negative (B-), positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut.