LED light indication Indication / fault code in Web UI OCPP fault code
Firm
IDLE (available) - (A) Vehicle not connected
IDLE (available) - (B) Vehicle connected not ready
IDLE (available) - (C) Vehicle connected ready
Blinking (3 blinks)
IDLE (available) - (A) Vehicle not connected
Blinking (30
second blink)
AUTHORIZED (available) - (A) Vehicle not connected
Firm
CHARGING (occupied) - (C) Vehicle connected ready
CHARGING (suspendedEV) - (B) Vehicle connected not ready
Blinking
Reserved
Firm
RCD triggered groundFailure
Residual current detected via sensor groundFailure
MCB of type 2 socket triggered overCurrentFailure
Actuator unlocked while charging connectorLockFailure
Plug locking failed connectorLockFailure
Possible CP and PR wiring issue. otherError
Blinking
UNAVAILABLE (unavailable) Unavailable
9