LED light indication Measure 1 Measure 2
NO LIGHT
Reset circuit breaker in upstream switchboard.
Have you tried everything
without success? Contact
installer or GARO Support
(please have M-number
available)
Check mainbreaker, reset it if it is deactivated.
Check mainbreaker (1-pole 10A), reset it if it is deactivated.
Verify that 12V power supply unit is receiving 220V AC power
via terminals L & N.
Disconnect red/black cables from the power supply unit terminals
marked "+/-".
If the power supply unit when red/black cables were
disconnected, then it has deteced an earth fault in one of the DC
powered components (controllers, upper PCB, router/switch etc.)
inside the charging station.
If LED-light [DC OK] remains turned off, consider replacing the
12V power supply unit.
Check red/black cable and connection between DC terminal
and upper PCB quick connection (located on far left side of
upper PCB in the charging station).
Verify that the controller has 12 V DC power supplied (4-pole
quick connection on down-side of controller -> terminal 1 & 2
from the left) and that the LED-light [Ready] is blinking green.
If power supply is ok, but no blinking green, then consider
replacing charging controller.
NO LIGHT
on right side
Verify that the cable (micro-USB on left controller and USB-A on
right controller) is properly connected and not damaged. Try
replacing with a new cable.
Have you tried everything
without success? Contact
installer or GARO Support
(please have M-number
available)