&Zn=S
Save phone no. in the location n of
NVRAM(n=0 - 3)
&Zn? Display phone no. in the location n
&ZL? Display the last executed phone no.
3.2 S-Register
The modem is structured to control and manage its operations employing S-
register. Followings are frequently-used functions.
S-
Resister
Range Unit Contents
S0 0 - 255 Rings
Number of Rings to Automatic
Answer
S1 0 - 255 Rings
Ring Counter
S2 0 -255 ASCII
Escape Character
S3 0 -127 ASCII
Line Termination Character
S4 0 - 127 ASCII
Command Line Editing
Character
S5 0 -255 ASCII
Command Line Editing
Character
S6 2 -255 S Wait Time for Dial Tone
S7 1 -255 S Wait Time for Carrier
S8 0 -255 S Pause Time for Dial Delay Modifier