User Manual

Page 24 709-RVC Manual
18. If equipped, connect the pump switch as required.
19. Verify that the battery voltage reads correctly. If it appears
low, make sure you have good wiring for the 12 volt power
and the ground.
20. The common alarm output provides a connection to ground
when the alarm is active. The maximum current that can be
put through the alarm output is 100mA, be sure to use a
relay if more current is required. Program and test the alarm
output to ensure that it functions as desired.
W WARNING: The pump switch is rated for a maximum of
7.5 amps. The use of a relay is required if more than 7.5 amps
is needed. A 7.5 amp (max) fuse must be installed in the series
with the 12V power circuit to the switch!