Item Description
Splice
• 10AWG (5.26mm²) extension wire, up to 4.6m (15ft.)
• 8AWG (8.36mm²) extension wire, up to 7m (23ft.)
• 6AWG (13.29mm²) extension wire, up to 11m (36ft.)
Fuse
8in. (20.3cm)
Battery
8in. (20.3cm)
Maximum extension 36ft. (11m)
Blink Codes
After the sonar module is installed, it turns on when the chartplotter is turned on. The color status LED on the
sonar module indicates its operational status.
LED Color State Status
Green Blinking
The sonar module is connected to a chartplotter and is operating
properly. You should see sonar data on the chartplotter.
Red Blinking
The sonar module is turned on, but is not connected to a chartplotter,
or is waiting to connect to a chartplotter. If the sonar module is
connected to the chartplotter and this code persists, check the wiring
connections.
Orange Blinking A software update is in progress.
Red/Green Blinking Reserved
Red
Two blinks followed by a
3-second pause
Other sonar failure.
Red
Three blinks followed by a
3-second pause
The transducer is not detected by the sonar module. If this code
persists, check the wiring connections.
Red
Five blinks followed by a
3-second pause
The sonar module input voltage exceeds the maximum input voltage.