Cockpit Reference Guide
Garmin G1000H Cockpit Reference Guide for the AgustaWestland AW119Kx
190-01515-00 Rev. B
81
Annunciations & Alerts
Flight
Instruments EIS
Com/Nav/
XPDR GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation Annun/Alerts Appendix Index
GIA 63H MESSAGE ADVISORIES (CONT.)
Message Comments
GIA1 SERVICE
– GIA1 needs
service. Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected
a problem in the unit. The system should be
serviced.
GIA2 SERVICE
– GIA2 needs
service. Return the unit for repair.
HW MISMATCH
– GIA hardware
mismatch. GIA1 communication
halted.
A GIA mismatch has been detected, where only
one is SBAS capable.
HW MISMATCH
– GIA hardware
mismatch. GIA2 communication
halted.
MANIFEST
– GIA1 software
mismatch, communication halted.
The GIA1 and/or GIA 2 has incorrect software
installed. The system should be serviced.
MANIFEST
– GIA2 software
mismatch, communication halted.
MANIFEST
– GFC software
mismatch, communication halted.
Incorrect servo software is installed, or gain
settings are incorrect.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The transmitter
is operating at reduced power. If the problem
persists, the system should be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
COM1 SERVICE
– COM1 needs
service. Return unit for repair.
The system has detected a failure in COM1 and/or
COM2. COM1 and/or COM2 may still be usable.
The system should be serviced when possible.
COM2 SERVICE
– COM2 needs
service. Return unit for repair.
COM1 PTT
– COM1 push-to-talk key
is stuck.
The COM1 and/or COM2 external push-to-talk
switch is stuck in the enable (or “pressed”)
position. Press the PTT switch again to cycle its
operation.
If the problem persists, the system should be
serviced.
COM2 PTT
– COM2 push-to-talk
key is stuck.