Cockpit Reference Guide
Embraer Prodigy
®
Touch Flight Deck 300 Cockpit Reference Guide
190-01536-00 Rev. A
154
Annunciations & Alerts
Flight
InstrumentsEAS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GDL 59 MESSAGE ADVISORIES
Message Comments
GDL59 CONFIG
– GDL 59
config error. Config service
req’d.
GDL 59 configuration settings do not match those of
backup configuration memory. The system should be
serviced.
GDL59 FAIL
– GDL 59 has
failed.
A failure has been detected in the GDL 59. The receiver
is unavailable. The system should be serviced.
GDL59 SERVICE
– GDL 59
needs service. Return unit for
repair.
A failure has been detected in the GDL 59. The system
should be serviced.
GDL59 RTR FAIL
– The GDL 59
router has failed.
A failure has been detected in the GDL 59 router. The
system should be serviced.
REGISTER GFDS
– Data
services are inoperative, register
w/GFDS.
The GDL 59 is not registered with Garmin Flight Data
Services, or its current registration data has failed
authentication.
GDL59 MANIFEST
–
GDL59 software mismatch,
communication halted.
The GDL 59 has incorrect software installed. The
system should be serviced.
GDR 66 VHF DATALINK TRANSCEIVER SYSTEM MESSAGES
System Message Comments
ATC MESSAGE
– <message>. Message has been received from ATC via CPDLC.
CPDLC
– CPDLC is available. Logon successful. Data link is available for use.
CPDLC
– CPDLC connection
lost. Establish new connection.
Data link connection has been lost.
CPDLC
– CPDLC facility logon
failed.
Logon failed. Check pertinent entries for accuracy.
CPDLC
– CPDLC data link
available. Logon is still required.
The data link is ready for use, but logon to the facility
has not yet taken place.
GDR TEMP
– GDR over temp.
Reducing transmitter power.
The system has detected an over temperature condition
in the GDR. The transmitter operates at reduced power.
If the problem persists, the system should be serviced.
GDR FAIL
– GDR is inoperative. A failure has been detected in the GDR. The system
should be serviced.