Cockpit Reference Guide

Embraer Prodigy
®
Touch Flight Deck 300 Cockpit Reference Guide
190-01536-00 Rev. A 119
Abnormal Operation
Flight
Instruments EAS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
ABNORMAL OPERATION
NOTE: The Phenom 300 Airplane Flight Manual (AFM) always takes
precedence over the information found in this section.
REVERSIONARY MODES
If a GDU fails or is off-line, the system provides the capability to show a PFD, an EIS
display, and a display pane on another GDU in Reversionary Mode.
The Phenom 300 employs dedicated three-position mode switches for PFD1 and
PFD2. These PFD mode switches allow for placing the GDUs in automatic, manual or
split-screen reversionary modes. The Split Mode selected using these switches is used
for viewing the reversionary display in a split screen format, unlike the Split Mode
Softkey on the PFD, which allows for viewing the normal display in a split screen
format. The following discussion illustrates some of the various reversionary mode
display combinations.
Auto Reversion
PFD1 failure, PFD1 Mode Switch set to AUTO, PFD2 Mode Switch set
to AUTO – MFD enters reversionary Full Mode and PFD2 continues to operate
normally.
MFD failure, PFD1 Mode Switch set to AUTO, PFD2 Mode Switch set
to AUTO – PFD1 operates normally when in Full Mode. If PFD1 is operating
in Split Mode, it will switch to Full Mode. PFD2 enters reversionary mode. If
PFD2 is operating in Split Mode, it will switch to reversionary Full Mode.
PFD2 failure – PFD1 and MFD continue to operate normally.
Manual Reversion
PFD1 Mode Switch set to REV, PFD2 Mode Switch set to AUTO – PFD1
and MFD enter reversionary Full Mode. PFD2 continues to operate normally.
PFD2 Mode Switch set to REV, PFD1 Mode Switch set to AUTO – PFD2
and MFD enter reversionary Full Mode. PFD1 continues to operate normally.
PFD1 and PFD2 Mode Switches set to REV – PFD1, MFD, and PFD2 enter
reversionary Full Mode.
PFD1 Mode Switch set to Split, PFD2 Mode Switch set to AUTO – PFD1
and MFD enter reversionary Split Mode. PFD2 continues to operate normally.
PFD2 Mode Switch set to Split, PFD1 Mode Switch set to AUTO – PFD2