504
APPENDIX A
ALERT LEVEL DEFINITIONS
The G1000 Alerting System, as installed in Cessna Corvalis/Corvalis TT aircraft, uses three alert levels.
•
WARNING:
This level of alert requires immediate pilot attention. A warning alert is annunciated in the
Annunciation Window and is accompanied by a continuous aural chime. Text appearing in the Annunciation
Window is RED. A warning alert is also accompanied by a flashing
WARNING
Softkey annunciation, as
shown in Figure A-2. Selecting the
WARNING
Softkey acknowledges the presence of the warning alert and
stops the aural chime.
•
CAUTION:
This level of alert indicates the existence of abnormal conditions on the aircraft that may require
pilot intervention. A caution alert is annunciated in the Annunciation Window and is accompanied by
a single aural chime. Text appearing in the Annunciation Window is YELLOW. A caution alert is also
accompanied by a flashing
CAUTION
Softkey annunciation, as shown in Figure A-2. Selecting the
CAUTION
Softkey acknowledges the presence of the caution alert.
•
MESSAGE ADVISORY:
This level of alert provides general information to the pilot. A message advisory
alert does not issue annunciations in the Annunciation Window. Instead, message advisory alerts only
issue a flashing
ADVISORY
Softkey annunciation, as shown in Figure A-2. Pressing the
ADVISORY
Softkey
acknowledges the presence of the message advisory alert and displays the alert text message in the Alerts
Window, and the softkey label changes to ALERTS.
Figure A-2 Softkey Annunciation (ALERTS Softkey Labels)
•Audio Alerting System: The System issues audio alert tones when specific system conditions are met. See
the Alert Level Definitions Section for more information. The annunciation tone may be tested from the
AUX - System Status Page.
Testing the system annunciation tone:
1) Use the FMS Knob to select the AUX - System Status Page.
2) Select the ANN TEST Softkey.
Or:
a) Press the MENU Key.
b) Highlight ‘Enable Annunciator Test Mode’ and press the ENT Key.
Selecting the audio alert voice:
1) Use the FMS Knob to select the AUX - System Setup Page.
2) Press the FMS Knob to activate the cursor.
3) Turn the large FMS Knob to highlight the voice in the Audio Alert Box.
4) Turn the small FMS Knob to select the desired voice, press the ENT Key.