System Maintenance Manual
Page 3-44 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision F 190-00682-01
3.9.4.14 Flight Charts Configuration
Follow this procedure to re-enable FliteCharts function if ChartView has been enabled for the G1000
system.
FliteCharts is a default G1000 system function. Section 3.9.8 installs the Terrain/Obstacle database card,
which includes FliteCharts database. If ChartView has not been enabled, the following procedure is not
required. If ChartView has previously been enabled, perform the procedure below to return FliteCharts
function to the G1000 system.
IMPORTANT!
This procedure will re-load the C90A/C90GT/C90GTi baseline configuration. Any
options previously enabled such as DME, ADF etc will need to be re-enabled per the
instructions contained in this document.
NOTE
The G1000 can only be configured for FliteCharts or ChartView but not both. Performing this procedure
will automatically disable the ChartView function.
1. With PFD 1 in Configuration Mode and the loader card inserted in the top card slot of PFD 1,
select the “System Upload” page on PFD 1 using the small FMS knob.
2.
Activate the cursor and use the small FMS knob to highlight “C90” in the AIRFRAME field. Press the
ENT key to select the airframe type.
3. Once the airframe type is selected the cursor moves to the FILE window. Rotate the small FMS
knob to activate the drop-down menu. Move the cursor to highlight “King Air C90 Baseline”
and press ENT.
NOTE
The PRODUCT window displays information regarding each G1000 LRU. The LRU column
depicts the reported software version of the LRU, whereas the CARD VERS column shows the
LRU software version stored on the Loader Card. The SOFTWARE and CONFIGURATION
columns default to having all required boxes checked. Each checked file is automatically loaded
to the correct G1000 LRU.
4. Press the LOAD softkey.
5. Observe software loading progress and verify software load completes without errors as
indicated by the following:
a. Green “PASS” or N/A in the Configuration column.
b. “Upload Complete………….COMPLETE” in the summary box.
6. Press ENT to acknowledge the “Upload Complete” box.
7. Reload other C90 options as appropriate per instructions contained within this document.