5.2.1.3 GIA CAN / RS-485 CONFIGURATION Page
GIA1 RS-485
Channel LRU Indicator Status
CHNL 1 GEA1
Green
GIA1/GEA1 data path is functioning correctly.
Red
GIA1/GEA1 data path is not functioning correctly.
Verify GEA1 is powered on using the GEA Status page.
Load GIA1 and GEA1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after swapping
units.
Swap GEA1 and GEA2, reconfigure both GEA’s to their new
locations to confirm if the problem is in the original GEA1.
o Replace original GEA1 if box turns green after swapping
units.
Check the GIA1/GEA1 interconnect wiring for faults.
Amber
GIA1/GEA1 data path functionality is unknown. Reload GIA1
configuration files.
CHNL 2 GEA2
Green
GIA1/GEA2 data path is functioning correctly.
Red
GIA1/GEA2 data path is not functioning correctly.
Verify GEA2 is powered on using the GEA Status page.
Load GIA1 and GEA2 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after swapping
units.
Swap GEA2 and GEA1, reconfigure both GEA’s to their new
locations to confirm if the problem is in the original GEA2.
o Replace original GEA2 if box turns green after swapping
units.
Check the GIA1/GEA2 interconnect wiring for faults.
Amber
GIA1/GEA2 data path functionality is unknown. Reload GIA1
configuration files.
CHNL 4 GFC 700
Green
GIA1/GFC 700 data path is functioning correctly.
Red
GIA1/GFC 700 data path is not functioning correctly.
Load GIA1 configuration files, GIA Gains file and GSA software
and gains file (if LRU and Card versions are different).
Reference GFC section for further troubleshooting.
Amber
GIA1/GFC 700 data path functionality is unknown. Reload GIA1
configuration files.