G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air Page 5-15
190-00716-01 Revision 4
GIA2 RS-232 (continued)
Channel LRU Indicator Status
CHNL 6
GRS 77 GRS
7800 #2
Green
GIA2/GRS 77 or GRS 7800 #2 data path is functioning
correctly.
Red
GIA2/GRS 77 or GRS 7800 #2 data path is not functioning
correctly.
Load GIA2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA2 if box turns green after
swapping units.
Swap GRS2 and GRS1 (no reconfiguration required) to
confirm if the problem is in the original GRS2.
o Replace original GRS2 if box turns green after
swapping units.
Check the GIA2/GRS 77 or GRS 7800 #2 interconnect wiring
for faults.
Amber
GIA2/GRS 77 or GRS 7800 #2 data path functionality is
unknown. Reload GIA2 configuration files.
CHNL 7
GMA
1347D #2
Green
GIA2/GMA 1347D #2 data path is functioning correctly.
Red
GIA2/GMA 1347D #2 data path is not functioning correctly.
Load GIA2 and GMA 1347D #2 configuration files.
Swap GMA 1347D #2 and GMA 1347D #1, reconfigure
both GMA’s to their new locations to confirm if the problem
is in the original GMA 1347D #2.
o Replace original GMA 1347D #2 if box turns green
after swapping units.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Check the GIA1/GMA 1347D #2 interconnect wiring for faults.
Amber
GIA1/GMA 1347D #2 data path functionality is unknown.
Reload GIA2 configuration files.