G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air Page 5-13
190-00716-01 Revision 4
GIA1 ARINC 429
Channel LRU Indicator Status
IN 5
GDC 7400
#1
Green
GIA1/GDC 7400 #1 data path is functioning correctly.
Red
GIA1/GDC 7400 #1 data path is not functioning correctly.
Load GIA1 and GDC 7400 #1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Check the GIA1/GDC 7400 #1 interconnect wiring for
faults.
Replace GDC 7400 #1 if problem remains.
Amber
GIA1/GDC 7400 #1 data path functionality is unknown. Reload
GIA1 configuration files.
IN 6
GRS 77 or
GRS 7800 #1
Green
GIA1/GRS 77 or GRS 7800 #1 data path is functioning
correctly.
Red
GIA1/GRS 77 or GRS 7800 #1 data path is not functioning
correctly.
Load GIA1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Swap GRS1 and GRS2 (no reconfiguration required, ref.
GRS Configuration and Testing sections) to confirm if the
problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the GIA1/GRS 77 or GRS 7800 #1 interconnect wiring
for faults.
Amber
GIA1/GRS 77 or GRS 7800 #1 data path functionality is
unknown. Reload GIA1 configuration files.