Page 3-58 G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Revision 4 190-00716-01
3.41 Optional ESP Enable
Follow this procedure to enable the Electronic Stability and Protection (ESP) function. An Enhanced
AFCS Unlock Card, as specified on General Arrangement Drawing 005-00629-02, will be required for
this procedure. Ensure that the “ESP Support (no AOA)” configuration has been loaded per Section 3.32.
NOTE
The G1000 has various features that require the use of unlock/enable cards to
activate the feature. Throughout this document these cards are generically
referred to as ‘enable cards’. In some cases, the actual label on the physical
card may say ‘unlock’. If uncertain, the technician should verify the card part
number prior to use. Coordinate this configuration with Section 7.26 “ESP
Functional Check”.
1. With the Enhanced AFCS Unlock card in the top slot of PFD1 and PFD1 in configuration mode,
select the “SYSTEM UPLOAD” page using the small FMS knob on PFD1.
2. Activate cursor and rotate the small FMS knob to display the drop down menu. Rotate the small
FMS knob to highlight “Enhanced AFCS” and press ENT key on PFD1.
3. Rotate the small FMS knob to highlight “King Air - Enable Enhanced AFCS”. Press ENT key
on PFD1.
4. Verify “King Air - Enable Enhanced AFCS” is displayed in the “Item” window. Press “LOAD”
softkey.
5. Monitor load progress. Verify software load completes without errors as indicated by the
following:
• Green “PASS” in the Configuration column for each item loaded.
• “Upload Complete………….COMPLETE” in the summary box.
6. Press ENT key on PFD1 to acknowledge upload complete.
7. De-activate the cursor.
8. Power down the system and remove the Enhanced AFCS Unlock Card from PFD1.