Cockpit Reference Guide
Garmin G1000 Cockpit Reference Guide for the Beechcraft 300/B300 Series
190-01344-01 Rev. A
Appendix
139
Flight
Instruments
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features Annun/Alerts Appendix Index
In some cases it may be necessary to obtain an unlock code from Garmin in order
to make the database product functional. It may also be necessary to have the system
configured by a Garmin authorized service facility in order to use some database
features.
If an error occurs during synchronization, an error message will be displayed,
followed by the affected display in the Sync Status section of the Database Window. If
synchronization completes on one display, but an error occurs on another, the error
message will be displayed with the affected diaplays listed after it. When an error
message is displayed, the problem must be corrected before synchronization can be
completed. A power cycle is required to restart synchronization when ‘Card Full’ or
‘Err’ is shown.
Error Message Description
Canceled Database synchronization has been canceled by removing the
bottom SD card in display being updated
Card Full SD card does not contain sufficient memory
Err Displayed for all other errors that may cause the synchronization
process to be halted
Timeout System timed-out prior to the database transfer completing
Loading Garmin Database Updates
1)
With system power OFF, remove the MFD database card from the bottom
card slot of the MFD.
2)
Update the Garmin databases on the MFD card.
3)
Insert the MFD database card into the bottom card slot of the MFD.
4)
Apply power to the system, check that the databases are initialized
and displayed on the power-up screen. When updating the terrain and
FliteCharts databases, a ‘Verifying’ message may be seen. If this message is
present, wait for the system to finish loading before proceeding to step 5.
5)
Acknowledge the Power-up Page agreement by pressing the ENT Key or
the right most softkey.
6)
Turn the large FMS Knob to select the AUX Page group on the MFD.
7)
Turn the small FMS Knob to select the System Status Page.
8)
Monitor the Sync Status in the Database Window. Wait for all databases to
complete synching, indicated by ‘Complete’ being displayed.