8.1.3 Display Failure Test
Step Desired Result
MFD Display Failure Conditions:
1. Open MFD CB.
2. Verify desired results.
3. Close MFD CB.
The following shall occur when power is removed
from the MFD:
MFD goes blank.
All PFD1 and 2 primary flight information is
retained.
The COM 1/2 and NAV 1/2 tuning fields remain
valid and can be tuned by rotating the tuning
knobs on PFD1 and PFD2.
XPDR 1/2 fields remain valid and XPDRs can
adjusted via PFD softkeys.
PFD2 Display Failure Conditions:
1. Open PFD 2 CB.
2. Verify desired results.
3. Close PFD 2 CB.
The following shall occur when power is removed
from PFD2:
PFD2 goes blank.
PFD1 and MFD remain in normal display formats.
The following illuminate on PFD1:
HDG NO COMP illuminates on PFD1
ROLL NO COMP illuminates on PFD1
PIT NO COMP illuminates on PFD1
IAS NO COMP illuminates on PFD1
ALT NO COMP illuminates on PFD1
GMA2 Fail – GMA2 is inoperative.
XPDR2 Fail – XPDR2 is Inoperative.
PFD1 Display Failure Conditions:
1. Open PFD 1 PRI and PFD1 SEC circuit
breakers.
2. Verify desired results.
3. Close PFD 1 PRI and PFD1 SEC circuit
breakers.
The following shall occur when power is removed
from PFD1:
PFD1 goes blank.
PFD2 and MFD remain in normal display formats.
The following illuminate on PFD2:
HDG NO COMP illuminates on PFD2
ROLL NO COMP illuminates on PFD2
PIT NO COMP illuminates on PFD2
IAS NO COMP illuminates on PFD2
ALT NO COMP illuminates on PFD2
GMA1 Fail – GMA1 is inoperative.
XPDR1 Fail – XPDR1 is Inoperative.