System Maintenance Manual

G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 5-17
190-00682-01 Revision F
IN 6 GRS 77 #2
GIA2/GRS 77 #2 data path is functioning correctly.
GIA2/GRS 77 #2 data path is not functioning correctly.
Load GIA2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns to a green
checkmark () after swapping units.
Swap GRS2 and GRS1 (no reconfiguration required) to
confirm if the problem is in the original GRS2.
o Replace original GRS2 if box turns to a green
checkmark () after swapping units.
Check the GIA2/GRS 77 #2 interconnect wiring for faults.
GIA2/GRS 77 #2 data path functionality is unknown. Reload
GIA2 configuration files.