System Maintenance Manual

G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 5-7
190-00682-01 Revision F
PFD 2 RS-232
Channel LRU Indicator Status
CHNL 2 GMC 710
PFD2/GMC 710 data path is functioning correctly.
PFD2/GMC 710 data path is not functioning correctly.
Verify GMC 710 is powered on.
o If GMC 710 will not power on, remove unit and
verify power and ground are present at the GMC
connector.
If power or ground is not present,
troubleshoot aircraft wiring for faults.
If power and ground are present, replace
GMC 710.
Load PFD2 and GMC 710 configuration files.
Swap PFD2 and PFD1 to confirm if the problem is in the
original PFD2.
o Replace original PFD2 if box turns to a green
checkmark () after swapping displays.
Check the PFD2/GMC 710 interconnect wiring for faults.
Replace GMC 710 if problem remains.
PFD2/GMC 710 data path functionality is unknown. Reload
PFD2 configuration file.