System Maintenance Manual

Page 7-16 G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
Revision 1 190-00716-01
Air Data System Test (Continued)
Test Point Altitude (FT) Airspeed (KTS)
Nominal
Altitude
AIR DATA 1 AIR DATA 2 AIR DATA 1 AIR DATA 2
ALT
AS
Tolerance Tolerance Tolerance Tolerance
Actual Actual Actual Actual
29000
111
28999
+/-72 +/-72 +/-2 +/-2
29000
130
28982
+/-72 +/-72 +/-2 +/-2
29000
150
28967
+/-72 +/-72 +/-2 +/-2
29000
169
28953
+/-72 +/-72 +/-2 +/-2
29000
188
28937
+/-72 +/-72 +/-2 +/-2
29000
196
28928
+/-72 +/-72 +/-2 +/-2
29000
212
28925
+/-72 +/-72 +/-2 +/-2
35000
97
35016
+/-87 +/-87 +/-2 +/-2
35000
114
34996
+/-87 +/-87 +/-2 +/-2
35000
130
34978
+/-87 +/-87 +/-2 +/-2
35000
147
34961
+/-87 +/-87 +/-2 +/-2
35000
164
34946
+/-87 +/-87 +/-2 +/-2
35000
171
34939
+/-87 +/-87 +/-2 +/-2
35000
185
34925
+/-87 +/-87 +/-2 +/-2
Aircraft S/N: _____________________ Date: __________________ Operator: ___________________
ADTS
Make: _______________________
Model: _______________________
S/N: _______________________
Cal. Date: _______________________
ADC1
Model: GDC 7400
P/N: 011-02337-____
S/N: ___________________
Cal. Date: ________________
ADC2
Model: GDC 7400
P/N: 011-02337-____
S/N: ___________________
Cal. Date: ________________
Leak Check Static System at 30,000 ft, 300 kts (pass if <300 ft in 1 min)
Pilot: _____________ Feet/Min
Copilot: ___________ Feet/Min
Leak Check Pitot System at 200 kts (pass if <1 KIAS in 1 min)
Pilot: _____________ KIAS/Min
Copilot: ___________ KIAS/Min