5.6.1 General Troubleshooting
The following annunciations may appear in the AFCS Annunciation field:
Table 5-3, AFCS Annunciation Troubleshooting
Annunciation Condition Resolution
AFCS System
Failure
Confirm AFCS Servos circuit breaker IN
Ensure that the G1000 system is in proper working order.
Check specifically for proper operation of the:
9 GIA 63 Integrated Avionics Units
9 GRS 77 AHRS Units
9 GDC 7400 Air Data Computers
9 All GSA 80 Servos
Check that no red X’s are present on the MFD and PFD
displays.
Check that no related alert messages are present on the
PFD displays (press the ALERTS softkey).
Go to the AUX SYSTEM STATUS page on the MFD and
verify that all LRUs have a ‘green’ check (see Section 5).
In Configuration mode, review the GFC 700 equipment
status, software, and certification gains.
Reload software, configuration, and certification gains to the
GIAs and GSA servos.
Check the GFC Status page for additional GFC 700 system
information.
Review the fault and assert logs for the GIAs and servos
(see Section 5.6.3)
Isolate the fault to an LRU. Replace this LRU and confirm
the resolution of the annunciation.
Pitch Axis Failure
Check the AUX – SYSTEM STATUS page to see if the
servo is online (green check).
Check that the affected servo is receiving power.
Check the servo wiring and connector.
For pitch trim, check pitch trim switch operation to verify
switch contacts are not stuck.
If failure condition still exists, remove and replace the
affected servo.
Pitch Trim Axis
Failure
Yaw Axis Failure
Roll Axis Failure
AHRS Monitor
Failure
If the AHRS inputs have been determined to be
“unreasonable” while the AP is engaged, in air, this message
will be displayed until AHRS inputs are determined
reasonable for 5 seconds.
Elevator Mis-Trim
Down
If elevator mistrim annunciations persist, check the pitch and
pitch trim servos for proper operation. Verify that the servo
is online at the AUX – SYSTEM STATUS page.
Check the servo wiring and connectors. Ensure the servo is
receiving power.
Check the aircraft control adjustments.
If mistrim condition still exists, remove and replace the
affected servo.
Elevator Mis-Trim
Up