3.31 Lightning System Option Configuration
Follow this procedure to enable the lightning system option (WX-500) for the G1000 system if required.
Follow Section 3.31.1 once the following steps are complete.
1. With the loader card in the top slot of PFD1 and PFD1 in configuration mode, select the System
Upload” page using the PFD1 small FMS knob.
2. Activate cursor and rotate the small FMS knob to display the drop down menu. Rotate the small
FMS knob to highlight “King Air – Airframe Options” and press ENT key on PFD1.
3. Rotate the small FMS knob to highlight “King Air - Lightning System Option”. Press ENT key
on PFD1.
4. Verify the “King Air - Lightning System Option” is displayed in the “Item” window. Press
LOAD” softkey.
5. Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green “PASS” in the Configuration column for each item loaded.
“Upload Complete………….COMPLETE” in the summary box.
6. Press ENT key on PFD1 to acknowledge upload complete.
7. Deactivate cursor.