Instruction Manual
G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air Page 3-23
190-00915-01 Revision 9
3.9.3 Software Load Confirmation
Anytime software and configuration loading procedures are accomplished during maintenance, conduct a
final software review of the system.
1. Start the PFD in Configuration Mode as described in Section 3.7.
2. Go to the System Status page using the FMS knob. Activate the cursor and toggle to the LRU
window.
3. Highlight each of the items in the LRU window by activating the cursor (pushing the FMS knob
as required) to verify the software part number and version displayed matches with the
information in the General Arrangement drawing (005-00421-03, “G1000/GFC 700 AFCS, King
Air 200/B200”).
IMPORTANT!
It is essential that the software versions be checked and matched against the listed versions in
the General Arrangement drawing listed in Table 1-2. Software Configuration is a critical part
of the G1000 operation and must be verified before returning an aircraft to service.
If any software version and/or part number does not match those specified by the General
Arrangement drawing, or if the software is not successfully loaded, DO NOT continue.
Troubleshoot and resolve the issue before continuing.