Instruction Manual

Page 3-22 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 9 190-00915-01
NOTE
The PRODUCT window displays information regarding each G1000 LRU. The LRU
column depicts the reported software version of the LRU, whereas the CARD VERS
column shows the LRU software version stored on the Loader Card. If an inequality
between the LRU VERS and CARD VERS columns is detected, the SOFTWARE and
CONFIGURATION boxes will be pre-selected (checked) for each LRU reporting a
different software version than the one on the card. The following softkeys provide an
easy way to select files:
CHK ALL: Selects all files, both configuration and software
CHK SW: Selects all SW files only.
CHK CFG: Selects all configuration files only.
CLR ALL: Clears all selections.
LOAD: Starts the software loading process.
NOTE
When loading a new software image or re-loading software to a particular LRU, it may
not be necessary to reload all software and configuration files. The technician should be
sure of the software requirements and load the appropriate files, including any options. If
there is any doubt, the CHK ALL softkey is recommended. Except where specifically
noted, the procedures that follow (including subsequent sections) are for 0985.07 and
later software versions. Earlier software versions have similar loading procedures and
may use slightly different nomenclature.
5. After verifying that the desired software and configuration files are checked, press the LOAD softkey.
The G1000 system automatically begins loading software and default configuration files to the
selected LRUs in the proper order.
Figure 3-19, Configuration/Software Load Page
6. Observe software loading progress and verify software load completes without errors as indicated by
the following:
Green “PASS” or White “N/A” in SOFTWARE and CONFIGURATION columns.
“Upload Complete………….COMPLETE” in the summary box.
7. Press PFD1 ENT key to acknowledge the “Upload Complete” box.
8. For system software version 0985.06 and later, load the GDC software and configuration per Section