5.9.4 Key Alerts
Failure Message Cause Solution
MFD1 “key” KEYSTK – key is
stuck.
The SYSTEM has determined a
key is stuck on MFD1.
Go to the GDU TEST page in
configuration mode and verify
key is stuck (if key is stuck the
corresponding indicator will be
green).
Exercise suspected stuck key
and reset GDU TEST page to
see if indicator remains green
without pressing the key.
9 If problem persists replace
the display.
PFD 1 “key” KEYSTK – key is
stuck.
The system has determined a key
is stuck on the PFD 1.
PFD 2 “key” KEYSTK – key is
stuck.
The system has determined a key
is stuck on the PFD 2.
5.9.5 Miscellaneous Alerts
Failure Message Cause Solution
XTALK ERROR – A flight display
cross talk error has occurred.
A communication error has
occurred between the MFD and/or
PFDs.
Ensure a database error has not
occurred (identified in the ALERTS
window on the PFD).
9 If a database error has
occurred, correct error before
proceeding.
Check display Ethernet
interconnect wiring.
Replace PFD1 with a known good
unit, to verify location of problem:
9 If problem persists, reinstall
original PFD1 and replace
PFD2.
9 If problem persists, reinstall
PFD2 and replace MFD.
DATA LOST – Pilot stored data
lost. Recheck settings.
Pilot stored data has been lost.
If the CLR key was held during
a power cycle, disregard
message.
Cycle power to PFD1:
9 Ensure CLR key is not
stuck on the GDU TEST
page.
9 If problem persists, replace
PFD1.