Instruction Manual

Page 5-18 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 9 190-00915-01
IN 6
GRS 77 or
GRS 7800 #2
Green
GIA2/GRS 77 or GRS 7800 #2 data path is functioning
correctly.
Red
GIA2/GRS 77 or GRS 7800 #2 data path is not functioning
correctly.
Load GIA2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Swap GRS2 and GRS1 (no reconfiguration required) to
confirm if the problem is in the original GRS2.
o Replace original GRS2 if box turns green after
swapping units.
Check the GIA2/GRS 77 or GRS 7800 #2 interconnect
wiring for faults.
Amber
GIA2/GRS 77 or GRS 7800 #2 data path functionality is
unknown. Reload GIA2 configuration files.