Instruction Manual

G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air Page 5-17
190-00915-01 Revision 9
GIA2 ARINC 429
Channel LRU Indicator Status
IN2
GRS 77 or
GRS 7800 #1
Green
GIA2/GRS 77 or GRS 7800 #1 data path is functioning
correctly.
Red
GIA2/GRS 77 or GRS 7800 #1 data path is not functioning
correctly.
Reload GIA2 configuration file.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the GIA2/GRS 77 or GRS 7800 #1 interconnect
wiring for faults.
Amber
GIA2/GRS 77 or GRS 7800 #1 data path functionality is
unknown. Reload GIA2 configuration files.
IN 5
GDC 74 #2
Or
GDC7400 #2
Green
GIA2/GDC #2 data path is functioning correctly.
Red
GIA2/GDC #2 data path is not functioning correctly.
Load GIA2 and GDC #2 configuration files.
Swap GIA2 and GIA1, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA2.
o Replace original GIA2 if box turns green after
swapping units.
Check the GIA2/GDC #2 interconnect wiring for faults.
Replace GDC #2 if problem remains.
Amber
GIA2/GDC #2 data path functionality is unknown. Reload
GIA2 configuration files.