Page 5-12 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 9 190-00915-01
GIA1 RS-232 (continued)
Channel LRU Indicator Status
CHNL 6
GRS 77 or
GRS 7800 #1
Green
GIA1/GRS 77 or GRS 7800 #1 data path is functioning
correctly.
Red
GIA1/GRS 77 or GRS 7800 #1 data path is not functioning
correctly.
Load GIA1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the GIA1/GRS 77 or GRS 7800 #1 interconnect wiring
for faults.
Amber
GIA1/GRS 77 or GRS 7800 #1 data path functionality is
unknown. Reload GIA1 configuration files.
CHNL 7
GMA
1347 #1
Green
GIA1/GMA 1347D #1 data path is functioning correctly.
Red
GIA1/GMA 1347D #1 data path is not functioning correctly.
Load GIA1 and GMA 1347D #1 configuration files.
Swap GMA 1347D #1 and GMA 1347D #2, reconfigure
both GMA’s to their new locations, to confirm if the
problem is in the original GMA 1347D #1.
o Replace original GMA 1347D #1 if box turns green
after swapping units.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Check the GIA1/GMA 1347D #1 interconnect wiring for faults.
Amber
GIA1/GMA 1347D #1 data path functionality is unknown.
Reload GIA1 configuration files.