PROPELLER TYPES AND INDICATOR MARKINGS
Manufacturer Hartzell Hartzell Hartzell Hartzell McCauley McCauley
Hub
HC-B3TN-3G
or -3N
HC-D4N-3A HC-E4N-3G HC–E4N-3A 3GFR34C702
4HFR34C771
4HFR34C754
Blades T10178()-3R
D9383K
Or
D9515K
D9390SK-1R NC9208K 100LA-2 94LA-0
Normal
Operating
Range – RPM
(Green Arc)
1600-2000 1150-2000 1180-2000 1180-2000 1600-2000 1100-2000
Maximum Limit
– RPM (Red
Radial)
2000 2000 2000 2000 2000 2000
Transient Limit
- RPM
2200 (1) 2200 (2) 2200 (2) 2200 (1) 2200 (1) 2200 (1)
Footnotes:
(1) This value is time limited to 5 seconds. Within the transient value, the torque indicator will display
green digits and a white pointer. After 5 seconds, the digits will flash alternating red and white
background with a flashing red pointer for 5 seconds. After 5 seconds of flashing, the indication
is steady white digits/red background and the pointer is red. Above 2200 RPM, the indication
immediately begins flashing for 5 seconds before displaying steady white digits on a red
background and a red pointer.
(2) This value is time limited to 20 seconds. Within the transient value, the torque indicator will
display green digits and a white pointer. After 20 seconds, the digits will flash alternating red and
white background with a flashing red pointer for 5 seconds. After 5 seconds of flashing, the
indication is steady white digits/red background and the pointer is red. Above 2200 RPM, the
indication immediately begins flashing for 5 seconds before displaying steady white digits on a red
background and a red pointer.