Instruction Manual

Page 5-14 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 9 190-00915-01
IN 6
GRS 77 or
GRS 7800 #1
Green
GIA1/GRS 77 or GRS 7800 #1 data path is functioning
correctly.
Red
GIA1/GRS 77 or GRS 7800 #1 data path is not functioning
correctly.
Load GIA1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Swap GRS1 and GRS2 (no reconfiguration required, ref.
GRS Configuration and Testing sections) to confirm if the
problem is in the original GRS1.
o Replace original GRS1 if box turns green after
swapping units.
Check the GIA1/GRS 77 or GRS 7800 #1 interconnect
wiring for faults.
Amber
GIA1/GRS 77 or GRS 7800 #1 data path functionality is
unknown. Reload GIA1 configuration files.