Instruction Manual

G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air Page 5-13
190-00915-01 Revision 9
GIA1 ARINC 429
Channel LRU Indicator Status
IN2
GRS 77 or
GRS 7800 #2
Green
GIA1/GRS 77 or GRS 7800 #2 data path is functioning
correctly.
Red
GIA1/GRS 77 or GRS 7800 #2 data path is not functioning
correctly.
Reload GIA1 configuration file.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Swap GRS1 and GRS2 (no reconfiguration required) to
confirm if the problem is in the original GRS2.
o Replace original GRS2 if box turns green after
swapping units.
Check the GIA1/GRS 77 or GRS 7800 #2 interconnect
wiring for faults.
Amber
GIA1/GRS 77 or GRS 7800 #2 data path functionality is
unknown. Reload GIA1 configuration files.
IN 5
GDC 74 #1
Or
GDC7400 #1
Green
GIA1/GDC #1 data path is functioning correctly.
Red
GIA1/GDC #1 data path is not functioning correctly.
Load GIA1 and GDC #1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns green after
swapping units.
Check the GIA1/GDC #1 interconnect wiring for faults.
Replace GDC #1 if problem remains.
Amber
GIA1/GDC #1 data path functionality is unknown. Reload
GIA1 configuration files.