Instruction Manual

Page 3-38 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 8 190-00915-01
3.24 POTS Handset Configuration
Follow this procedure to enable a POTS handset if installed. Note that the GDL 59 wi-fi data link option
must be loaded per Section 3.21 prior to loading the POTS handset configuration.
1. Power up the PFD1 in configuration mode.
2. On the PFD1, select GDL page group using the large FMS knob.
3. Using the small FMS knob select the GDL 59 Configuration page.
4. Activate the cursor. Use the large FMS knob to select POTS CONNECTED in the PHONE
SETTINGS field.
5. Use the small FMS knob to select YES and press the ENT key.
6. After GDL 59 is configured, press the ENT key.
3.25 GSM 85A Servo Mount Configuration
For software versions 0985.04 and later, the section 4.9.1 slip clutch torque check procedure requires the
correct type of GSM servo gearbox to be configured. It is not required to load this configuration if
GSM 86 servo gearboxes are installed for all servos (default configuration.)
1. With the loader card in the top slot of PFD1 and PFD1 in configuration mode, select the “SYSTEM
UPLOAD” page using the small FMS knob on PFD1.
2. Activate cursor and rotate the small FMS knob to display drop down menu. Highlight King Air - Options
and press ENT key on PFD1.
3. Rotate the small FMS knob to highlight “King Air 200/B200 – GSM 85A Servo Mounts”. Press ENT
key on PFD1.
4. Verify “King Air 200/B200 – GSM 85A Servo Mounts” is displayed in the “Item” window.
5. Deselect any servos that have GSM 86 servo gearboxes installed by scrolling to the servo and pressing
ENT key on PFD1.
6. When all of the servos that have GSM 85A servo gearboxes are selected, press “LOAD”.
Figure 3-36, GSM 85A Servo Mount Configuration
7. Monitor load progress. Verify software load completes without errors as indicated by the following:
Green “PASS” in Configuration column for PITCH SERVO, PITCH TRIM SERVO, ROLL SERVO
and/or YAW SERVO (as selected).
“Upload Complete………….COMPLETE” in the summary box.
8. Press ENT key on PFD1 to acknowledge upload complete.
9. Deactivate cursor.
10.
Verify the servo mount configuration per section 3.27.