3.11 TAWS-A Voice No Callout Option Configuration
This section applies only to installations with the TAWS-A option. If TAWS-A voice callouts (400,
300, 200, 100) are not desired, follow the procedures outlined in this section to load the necessary
configuration files to disable TAWS-A voice callouts.
1. With the loader card in the top slot of PFD1 and PFD1 in configuration mode, select the “SYSTEM
UPLOAD” page using the small FMS knob on PFD1.
2. Activate cursor and rotate the small FMS knob to display drop down menu. Highlight King Air - Options
and press ENT key on PFD1.
3. Rotate the small FMS knob to select “TAWS-A No Voice Callout Installation Option”. Press ENT key on
PFD1.
4. Verify the “TAWS-A No Voice Callout Installation Option” is displayed in the “Item” window. Press
“LOAD”.
Figure 3-22, TAWS-A Voice No Callout Configuration
5. Monitor load progress. Verify software load completes without errors as indicated by the following:
• Green “PASS” in Configuration column for AIRFRAME.
• “Upload Complete………….COMPLETE” in the summary box.
6. Press ENT key on PFD1 to acknowledge upload complete.
7. Deactivate cursor.