3.19 Stormscope (WX-500) Configuration Load Confirmation.
1. With PFD1 in configuration mode, use the PFD1 large FMS knob to select OTHER and the
Stormscope configuration page.
Figure 3-30, Stormscope Configuration Page
2. Activate the cursor to highlight the DATA field. Use the small FMS knob to open the drop down
menu then select ‘Config’ and press ENT key on the PFD1.
Figure 3-31, Stormscope Configuration
3. Verify that the DATA window shows the following:
Hdg: None: J3-1 Jumper
J3-2 Jumper
Hdg Valid Flag No Fla
Flag Sense +invld
J3-4 Open
Hdg Value <aircraft heading>
Inhibit Line Off
Antenna Mount Bottom
J3-3 Open
4. Deactivate the cursor.
NOTE