System Maintenance Manual

Page 3-28 G1000 / GFC 700 System Maintenance Manual - 200/B200 Series King Air
Revision 7 190-00915-01
3.14 DME Option Configuration
This section loads the necessary configuration files for those aircraft equipped with a DME.
1. With the loader card in the top slot of PFD1 and PFD1 in configuration mode, select the “SYSTEM
UPLOAD” page using the small FMS knob on PFD1.
2. Activate cursor and rotate the small FMS knob to display drop down menu. Highlight King Air - Options
and press ENT key on PFD1.
3. Rotate the small FMS knob to highlight “DME Option”. Press ENT key on PFD1.
4. Verify the “DME Option” is displayed in the “Item” window. Press “LOAD”.
Figure 3-25, DME Configuration
5. Monitor load progress. Verify software load completes without errors as indicated by the following:
Green “PASS” in Configuration column for GIA1, GMA PIL and GMA COPIL.
“Upload Complete………….COMPLETE” in the summary box.
6. Press ENT key on PFD1 to acknowledge upload complete.
7. Deactivate cursor.