System Maintenance Manual
Page 5-54 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision G 190-00682-01
Failure Message Cause Solution
MFD1 SERVICE – needs service.
Return unit for repair.
The G1000 has determined MFD1
needs service.
• Ensure the MFD connector is
fully seated and locked.
• If the unit was started in a very
dark environment the photocells
may not have enough light to
initially raise the CCFT level.
Go to the GDU STATUS page
in configuration mode, ensure
CCFT CRNT 1 & 2 levels are
above 50.
If the CCFT levels are not
above 50, apply light to the
photocell and observe if the
CCFT level rises.
If the CCFT level rises,
disregard the message.
If the CCFT level does not
rise, replace the MFD
•
Replace the MFD
PFD 1 SERVICE – needs service.
Return unit for repair.
The G1000 has determined
the specified PFD needs
service.
• Ensure the PFD connector is
fully seated and locked.
• If the unit was started in a very
dark environment the photocells
may not have enough light to
initially raise the CCFT level.
Go to the GDU STATUS page
in configuration mode, ensure
CCFT CRNT 1 & 2 levels are
above 50.
If the CCFT levels are not
above 50, apply light to the
photocell and observe if the
CCFT level rises.
If the CCFT level rises,
disregard the message.
If the CCFT level does not
rise, replace the PFD
•
Replace the PFD.
PFD 2 SERVICE – needs service.
Return unit for repair.
PFD 1 VOLTAGE – PFD 1 has
low voltage. Reducing power
usage.
The specified PFD supply
voltage is low.
• Check input voltage to PFD.
•
If input voltage is ok, replace
PFD.
.
PFD 2 VOLTAGE – PFD 2 has
low voltage. Reducing power
usage.
MFD1 VOLTAGE – MDF1 has
low voltage. Reducing power
usage.
The MFD supply voltage is
low.
• Check input voltage to MFD.
•
If input voltage is ok, replace
MFD.