System Maintenance Manual

Page 5-52 G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air
Revision G 190-00682-01
Failure Message Cause Solution
DB MISMATCH – Airport Terrain
database version mismatch. Xtalk
is off.
The PFDs and/or MFD have
different Airport Terrain database
versions installed.
Confirm supplemental data card is
inserted fully.
Reload the database or replace the
supplemental datacard.
DB MISMATCH – Terrain
database version mismatch.
The PFDs and/or MFD have
different terrain database versions
installed.
DB MISMATCH – Obstacle
database version mismatch.
The PFDs and/or MFD have
different obstacle database
versions installed.
DB MISMATCH – Terrain
database type mismatch.
The PFDs and/or MFD have
different terrain database types
installed (i.e., different regions:
Americas, International, Atlantic,
etc).
5.9.3 Cooling Alerts
Failure Message Cause Solution
MFD1 COOLING – has poor
cooling. Reducing power usage.
MFD1 has exceeded its operating
temperature range.
Check cooling fan and wiring
for proper operation (if
applicable).
Replace cooling fan if
unable to determine if
operating correctly.
If problem persists, replace
the MFD.
If problem continues contact
Garmin Aviation Product Support
for assistance.
PFD 1 COOLING – has poor
cooling. Reducing power usage.
PFD 1 has exceeded its operating
temperature range.
Check cooling fan and wiring
for proper operation (if
applicable).
Replace cooling fan if
unable to determine if
operating correctly.
If problem persists, replace
the PFD1.
If problem continues contact
Garmin Aviation Product Support
for assistance.
PFD 2 COOLING – has poor
cooling. Reducing power usage.
PFD 2 has exceeded its operating
temperature range.
Check cooling fan and wiring
for proper operation (if
applicable).
Replace cooling fan if
unable to determine if
operating correctly.
If problem persists, replace
the PFD2.
If problem continues contact
Garmin Aviation Product Support
for assistance.