System Maintenance Manual

G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 5-13
190-00682-01 Revision G
IN 6 GRS 77 #1
GIA1/GRS 77 #1 data path is functioning correctly.
GIA1/GRS 77 #1 data path is not functioning correctly.
Load GIA1 configuration files.
Swap GIA1 and GIA2, reconfigure both GIA’s to their new
locations to confirm if the problem is in the original GIA1.
o Replace original GIA1 if box turns to a green
checkmark () after swapping units.
Swap GRS1 and GRS2 (no reconfiguration required, ref.
GRS Configuration and Testing sections) to confirm if the
problem is in the original GRS1.
o Replace original GRS1 if box turns to a green
checkmark () after swapping units.
Check the GIA1/GRS 77 #1 interconnect wiring for faults.
GIA1/GRS 77 #1 data path functionality is unknown. Reload
GIA1 configuration files.