System Maintenance Manual
G1000/GFC700 System Maintenance Manual – C90A/C90GT/C90GTi King Air Page 5-5
190-00682-01 Revision G
NOTE
Reference Table 3-1 for interpretation of data indicator symbols
The box next to each channel indicates the current status of the channel per the below:
• Red X = data path is known to be failed
• Amber question mark (?) = data path status is unknown
• Green checkmark ()= data path is known to be good
The applicable data paths can be verified by viewing the configuration mode pages listed below.
5.2.1.1 GDU RS-232 / ARINC 429 CONFIG Page
PFD 1 RS-232
Channel LRU Indicator Status
CHNL 2 GMC 710
PFD1/GMC 710 data path is functioning correctly.
PFD1/GMC 710 data path is not functioning correctly.
• Verify GMC710 is powered on.
o If GMC 710 will not power on, remove unit and
verify power and ground are present at the GMC
connector.
If power or ground is not present,
troubleshoot aircraft wiring for faults.
If power and ground are present, replace
GMC 710.
• Load PFD1 and GMC 710 configuration files.
• Swap PFD1and PFD2 to confirm if the problem is in the
original PFD1.
o Replace original PFD1 if box turns to a green
checkmark (√) after swapping displays.
• Check the PFD1/GMC 710 interconnect wiring for faults.
Replace GMC 710 if problem remains.
PFD1/GMC 710 data path functionality is unknown. Reload
PFD1 configuration file.