- Specifications
Item Description
Power source
Power cable
Horn
Lamp
Relay (1 A coil current)
Toggle switches to enable and disable lamp or horn alerts
Item Wire Color Wire Function
Red Power
Black Ground
Yellow Alarm
Composite Video Considerations
This chartplotter allows video input from composite video
sources using the port labeled CVBS IN. When connecting
composite video, you should observe these considerations.
• The CVBS IN port uses a BNC connector. You can use a
BNC to RCA adapter to connect a composite-video source
with RCA connectors to the CVBS IN port.
• Video is shared across the Garmin Marine Network, but it is
not shared across the NMEA 2000 network.
Specifications
All Models
Temperature range From -15° to 50°C (from 5° to 122°F)
Material Polycarbonate plastic and die-cast
aluminum
Water rating IEC 60529 IPX7
1
Input voltage From 10 to 32 Vdc
Fuse 6 A, 125 V fast-acting
NMEA 2000 LEN @ 9 Vdc 2
NMEA 2000 draw 75 mA max.
Compass-safe distance 65 cm (25.5 in.)
Memory card 2 SD
®
card slots; 32 GB max. card size
Wireless frequency, transmit
power
2.4 GHz @ 15.26 dBm maximum
10x2 Models
Dimensions (W x H x D) 31.8 x 18.5 x 6.9 cm (12.5 x 7.3 x 2.7
in.)
Display size (W x H) 22.4 x 12.5 cm (8.8 x 4.9 in.)
10.1 in. diagonal
Weight 1.85 kg (4.1 lb.)
Max. power usage at 10 Vdc 32.4 W
Typical current draw at 12 Vdc 1.9 A
Max. current draw at 12 Vdc 2.7 A
12x2 Models
Dimensions (W x H x D) 35.8 x 22.6 x 6.9 cm (14.1 x 8.9 x 2.7
in.)
Display size (W x H) 26.2 × 16.3 cm (10.3 × 6.4 in.)
12.1 in. diagonal
Weight 2.34 kg (5.15 lb.)
Max. power usage at 10 Vdc 34.8 W
Typical current draw at 12 Vdc 2.2 A
Max. current draw at 12 Vdc 2.9 A
1
The device withstands incidental exposure to water of up to 1 m for up to 30 min.
For more information, go to www.garmin.com/waterrating.
NMEA 2000 PGN Information
Transmit and Receive
PGN Description
059392 ISO acknowledgment
059904 ISO request
060160 ISO transport protocol: Data transfer
060416 ISO transport protocol: Connection management
060928 ISO address claimed
065240 Commanded address
126208 Request group function
126996 Product information
126998 Configuration information
127237 Heading/track control
127245 Rudder
127250 Vessel heading
127258 Magnetic variance
127488 Engine parameters: Rapid update
127489 Engine parameters: Dynamic
127493 Transmission parameters: Dynamic
127505 Fluid level
127508 Battery status
128259 Speed: Water referenced
128267 Water depth
129025 Position: Rapid update
129026 COG and SOG: Rapid update
129029 GNSS position data
129283 Cross track error
129284 Navigation data
129539 GNSS DOPs
129540 GNSS satellites in view
130060 Label
130306 Wind data
130310 Environmental parameters (obsolete)
130311 Environmental parameters (obsolete)
130312 Temperature (obsolete)
Transmit
PGN Description
126464 Transmit and receive PGN list group function
126984 Alert Response
127497 Trip parameters: Engine
Receive
PGN Description
065030 Generator average basic AC quantities (GAAC)
126983 Alert
126985 Alert text
126987 Alert threshold
126988 Alert value
126992 System time
127251 Rate of turn
127257 Attitude
127498 Engine parameters: Static
127503 AC input status (obsolete)
127504 AC output status (obsolete)
127506 DC detailed status
127507 Charger status
127509 Inverter status
128000 Nautical leeway angle
5