Installation Instructions
12 GHP 10V Installation Instructions
Connecting an Optional GPS Device to the GHP 10V Autopilot System
To use an optional optional GPS device with the GHP 10V, either connect a NMEA 2000-compatible GPS device to the NMEA 2000 network,
or connect a NMEA 0183-compatible GPS device directly to the GHC 10.
To connect an optional NMEA 2000-compatible GPS device to your GHP 10V:
1. Add an additional T-connector (not included) for the optional GPS device you want to add to the NMEA 2000 network.
2. Connect the GPS device to the T-connector by following the instructions provided with the GPS device.
To connect an optional NMEA 0183-compatible GPS device to your GHP 10V:
1. Determine the NMEA 0183 wiring assignments of your NMEA 0183-compatible GPS device.
2. Use the GHC 10 power/data cable wiring diagrams to correctly wire your NMEA 0183-compatible GPS device.
3. Use 22 AWG twisted-pair wire for extended runs of wire.
4. Solder and cover all bare-wire connections.
>
>
>
>
GHC 10
Device
Color Function
Power
Ground
CCU Signal
Tx/A(+)
Tx/B(-)
Rx/A(+)
Rx/B(-)
Red
Black
Yellow
Blue
White
Brown
Green
Fuse
1 A
GHC 10 Power/Data Cable
Example:
Wiring the GHC 10 to a NMEA 0183-Compatible Device
+
-
>
>
>
>
>
>
>
>
RED
BLACK
BROWN
GREEN
WIRE
COLOR
WIRE
FUNCTION
POWER
POWER GND
NMEA GND
Tx/A (+)
Tx/B (-)
NMEA 0183-
Compatible
Device
GHC 10
Device
Battery
12 Vdc
Fuse
1 A
BLUE
WHITE
YELLOW
Rx/A (+)
Rx/B (-)
to CCU
Notes:
Consult the installation instructions for your NMEA 0183-compatible device to identify the Transfer (Tx) A(+) and B(-) wires.
If your NMEA 0183-compatible device has only one transmitting wire (Tx), connect it to the brown wire (Rx/A) from the GHC 10, and
connect the green wire (Rx/B) to ground.
If your NMEA 0183-compatible device has only one receiving wire (Rx), connect it to the blue wire (Tx/A) from the GHC 10, and leave the
white wire (Tx/B) unconnected.
The yellow (CCU signal) wire must be wired to the yellow wire of the CCU cable.
•
•
•
•