Instruction Manual
Instructions for Continued Airworthiness 190-01190-11 Rev. 1
for G500H in Robinson R44 Series Rotorcraft Page 8 of 20
Item Interval Description/Procedure
Garmin Glareshield
Assembly
100 Hours/12
Calendar
Months
Coincident with upper console 100 hour inspection per Robinson
Model R44 Maintenance Manual, Change 13 October 2006, or
later ,page 2.16, perform -
1. Visual inspection of composite glare shield assembly,
Garmin PN 011-02759-00 (28VDC electrical system), or
011-02759-01 (14VDC electrical system) for damage.
Inspect for loose rivets indicated by cracks in composite
or aluminum components, or paint. Contact Garmin
customer support for glare shield replacement
components.
2. Check tightness of instrument panel hinge mounting
screws, glare shield shear web mounting screws, and
vibration restraining bracket mounting screws. Re-torque
loose fasteners per Section 1.320 of Robinson Model
R44 Maintenance Manual, Change 13 October 2006, or
later, page 1.22.
3. Check tightness of mounting screws attaching instrument
panel to glare shield. Re-torque loose fasteners per
Section 1.320 of Robinson Model R44 Maintenance
Manual, Change 13 October 2006, or later, page 1.22.
GDU 620, GRS 77H,
GDC 74H, GMU 44, GTP
59
100 Hours/12
Calendar
Months
Conduct a visual inspection (look for signs of wear, deterioration,
or damage to wires, backshells, or connectors) on units and their
wire harnesses to ensure installation integrity:
1. Gain access to LRU (see section 2.2 for LRU locations)
2. Inspect each unit for security of attachment.
3. Inspect all knobs and buttons for legibility.
4. Inspect condition of wiring, routing and
attachment/clamping.
5. Inspect integrity of shield terminations.
6. Inspect for signs of corrosion on equipment and their rack
installations.