f) GTP 59 OAT Probe Installation
The GTP 59 OAT Probe is located on the existing belly panel between station 2437 and
2351. (Figure 6-06)
Access Removal and Installation Methods
i. Removal
1. Un-latch the Center lower belly access panel.
2. Disconnect the retaining straps that prevent the panel from falling to the floor.
3. If other aftermarket items are attached to the Center lower belly panel it may be
necessary to remove or disconnect them in order to remove the lower belly panel.
Consult the manufacturers Installation and Removal instructions for proper
removal of items.
ii. Installation
1. Re-install any other aftermarket items if removed to gain access to the air data
computer. Consult the manufacturers Installation and Removal instructions for
proper installation of items.
2. Connect the retaining strap that was disconnected to gain access to the air data
computer.
3. Close the Center lower belly access panel and latch it.
Caution: Use of power tools during removal or installation of
panels and attaching hardware may damage nut plates or
deform holes in composite doors, covers, panels, and fairings
06-00-00
Figure 6-06
GTP 59
STA
2351
REF
STA
2437
REF