Owner's manual

Dimensions and Technical Specifications Garland RTCSmp Induction Built-in Griddles
8 Part # 4532291 Rev 2 (01/15/14)
3.5 Operating Conditions
Max. Tolerance of Nominal Supply Voltage +6 /-10 %
Supply frequency 50/60 Hz
Ingress Protection class IP X0
In Storage > -4°F to +158°F (-20°C to +70°C)
In Operation >+ 41°F to +104°F (+5°C to +40°C)
Maximum Relative Air Humidity In Storage > 10% to 90%
In Operation > 30% to 90%
Maximum fan air flow: 88.29cfm/150m
3
per hour and min. opening: 16.59in
2
/10700mm
2
is required.
3.6 Compliances
North American models:
ETL listed in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001
CE models comply with the latest European Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)
Patents: Europatent EP 0858722, Swiss patent 695817, US 7183525 B2